Copyright © 2010, Juniper Networks, Inc.
Errata
63
Release 11.1.1
If you enter the
no ethernet oam lfm link-monitor symbol-period
command without
specifying the threshold or window parameters, both the configured threshold and
window attributes are removed. If you want to delete only one of the two settings,
such as the threshold value or the period of time for monitoring symbol errors, you
can use the keyword specific to the setting that you want to remove with the
no
ethernet oam lfm link-monitor symbol-period
command.
z
In the
JunosE Command Reference Guide A to M
, the description of the
mpls ldp
graceful-restart reconnect-time
command incorrectly states that the
no
version
restores the default value of 120 seconds. The correct default value is 140 seconds.
z
The
JunosE Command Reference Guide N to Z
omits the description of the
show
memory-management protection
command, beginning with JunosE Release 7.1.0 in
which it was introduced.
The
show memory-management protection
command is available in Privileged
Exec mode. You can use this command to display the information about memory
management protection of the router.
The syntax for this command is:
show memory-management protection [detail] [
filter
]
The command can be used only in the support mode and is not user configurable.
z
In the
JunosE System Event Logging Reference Guide
, for the radiusClient event
category, the Error field incorrectly includes the following errors:
−
Internal allocation error of base RADIUS server table
−
Invalid virtual router for user's context
These errors were never implemented in any version of JunosE Software.