JunosE 11.1.1 Release Notes
62
Errata
Copyright © 2010, Juniper Networks, Inc.
Using this syntax, you are not required to specify a threshold value or a time period.
Both the
threshold
and
window
keywords are optional when you use the
no
form of
this command.
If you enter the
no ethernet oam lfm link-monitor frame-seconds
command
without specifying the threshold or window parameters, both the configured
threshold and window attributes are removed. If you want to delete only one of the
two settings, such as the threshold value or the period of time for error frames
monitoring, you can use the keyword specific to the setting that you want to remove
with the
no ethernet oam lfm link-monitor frame-seconds
command.
z
The syntax of the
no
version of the
ethernet oam lfm link-monitor
frame-seconds-summary
command in the
JunosE Command Reference Guide A to M
is incorrect. This erroneous syntax indicates that you are required to specify either the
threshold value or the period of time during which errored frame seconds are counted
(the window).
The incorrect syntax is as follows:
no ethernet oam lfm link-monitor frame-seconds-summary { threshold { high {
highFrames
| none } | low
lowFrames
} | window
period
}
The correct syntax of the
no
version of this command is as follows:
no ethernet oam lfm link-monitor frame-seconds-summary [ threshold { high {
highFrames
| none } | low
lowFrames
} | window
period
]
Using this syntax, you are not required to specify a threshold value or a time period.
Both the
threshold
and
window
keywords are optional when you use the
no
form of
this command.
If you enter the
no ethernet oam lfm link-monitor frame-seconds-summary
command without specifying the threshold or window parameters, both the
configured threshold and window attributes are removed. If you want to delete only
one of the two settings, such as the threshold value or the period of time for
monitoring errored frame seconds, you can use the keyword specific to the setting
that you want to remove with the
no ethernet oam lfm link-monitor
frame-seconds-summary
command.
z
The syntax of the
no
version of the
ethernet oam lfm link-monitor symbol-period
command in the
JunosE Command Reference Guide A to M
is incorrect. This erroneous
syntax indicates that you are required to specify either the threshold value or the
period of time during which symbol errors are counted (the window).
The incorrect syntax is as follows:
no ethernet oam lfm link-monitor symbol-period { threshold { high {
highFrames
|
none } | low
lowFrames
} | window
period
}
The correct syntax of the
no
version of this command is as follows:
no ethernet oam lfm link-monitor symbol-period [ threshold { high {
highFrames
|
none } | low
lowFrames
} | window
period
]
Using this syntax, you are not required to specify a threshold value or a time period.
Both the
threshold
and
window
keywords are optional when you use the
no
form of
this command.