background image

A2 Ethernet Multi Dock

The A2 Ethernet Multi Dock is a mounting station for up to 

four Archer 2 and/or Allegro 2 Rugged Handhelds. It provides 

ethernet ports for networking and a power input jack to apply 

power to the dock and to charge handhelds.

Ethernet Specifications

 

„

10/100 Mbps twisted-pair ethernet

 

„

IEEE802.3 10Base-T / 100Base-TX

 

„

Manages twisted pair crossover detection and correction

 

„

Supports full-duplex and half-duplex

 

„

Ethernet driver software pre-installed on the handheld

Dock Features

Accessories 

Included with the Multi Dock

 

 

„

Archer 2 insert and 2 screws (4 sets)

 

„

AC universal power adapter 

 

„

US AC power cord (adapters for international plugs are 

available separately from Juniper Systems or your dealer)

 

„

RJ-45 CAT5 twisted-pair 7 foot ethernet cable

Accessories Available Separately

 

„

Docking I/O modules for the handhelds if they are not 

factory installed (available from Juniper Systems or your 

dealer)

 

„

Communication software to communicate with the 

handheld over an ethernet network (options include 

custom software or programs from a third party vendor 

such as Soti MobiControl, 

www.soti.net/mobicontrol

 or 

AirWatch, 

www.air-watch.com

 

„

Three #6-32 screws to mount the dock to a surface 

(optional)

 

1

  Handheld backrest and connector protector slot

 

2

  LED indicator: green when the dock has power

 

3

  Docking pins

 

4

  Power input jack: 12VDC power input to power the Ethernet dock 

and the handheld(s)  

 

5

  Archer 2 insert location (use as needed)

 

 

6

  Ethernet port (1 of 2): for networking using an ethernet cable and 

software. LED indicators: 
-  Left LED lights amber to indicate that data connection is active 
-  Right LED lights green when there is a 100 Mbps connection     
    speed

4

6

2

1

5

3

Using the A2 Ethernet Multi Dock

1.

 

  The ethernet dock is a freestanding desktop base. It can 

also be mounted to a horizontal surface like a desk or 

shelf. To mount the dock, drill three holes in a horizontal 

line 10 7/8” (27.65 cm) apart up through the mounting 

surface. Screw #6-32 screws up into the threaded holes in 

the dock’s bottom base plate. 

 

Note: The screws should not penetrate the dock more than 1/4”.

2.

  Handhelds must have a docking I/O module. The lower 

right side of the module has docking pin contacts as 

shown below:

 

 

If you have a standard I/O module, replace it with a 

docking I/O module. Follow the instructions included 

with the kit.

3.

  To use an Archer 2 with the dock, install the insert as 

shown below. This step is not required for the Allegro 2. 

4.

  Attach the AC power cord to the power adapter. Plug 

the power cord into an AC power supply and the power 

adapter into the power input jack on the dock. This 

provides power to the dock and charges handhelds. The 

green LED turns on when power is applied. 

5. 

  If a handheld has a connector protector, open it to reveal 

the connector ports. Pull it back as shown below.  

6.

  To insert a handheld, hold it so the connector ports are 

at the bottom and the keypad is facing forward. Insert 

the handheld into the dock as shown below so it is firmly 

seated. The handheld automatically turns on.  

7

.  When you insert a handheld into the dock, a red LED on 

the handheld is illuminated, indicating that it is properly 

docked and ready to communicate over the network.

8.

  For networking, use an ethernet cable to connect the dock 

to an ethernet switch or to an internal network.

9.

  Use communication software to communicate with 

the handhelds over an ethernet network. Follow the 

instructions included with the software. 

10.

  Handhelds can be used when they are in the dock. The 

keys and display are accessible.