39
D*AP LM 4
Web GUI – EVENTS – Preset Events – Audio Processor
Important Note! The Preset Events tab controls multiple preset categories which are represented by the
page embedded tabs "System!, "Interface", "Routing" and "Audio Processor".
You must be aware that one trigger is valid for an entire line from System over Routing to Audio Processor.
If you change the Trigger on one of the embedded pages it will be changed on all other pages.
Web GUI – EVENTS – Action Events – GPO
Action events – Comprises of two options. Creating GPO control signals, and invoking Loudness
Measurement “Start”, “Stop” and “Pause” commands.
The LM 4 has 8 physical GPO's (relay change over contacts) which may be incorporated into an action
event. The example below will only activate GPO 1 if the "SDI alarm" event is triggered by the SDI lost"
trigger.
Action Events are independent from Preset Events. That is why you must define a new event name
(e.g. SDI alarm). This event should be triggered by the "SDI lost" trigger, which you set up on the trigger
pane (third one) :