25
D*AP LM 4
Link
[Linked / Unlinked]
defines the coupling of the control circuits in order to maintain the
listening balance for correlated signals and to provide a grouping of the
setup parameters for two channel signals.
Input
[Enable / Disable]
here there are numerous pre-conditioning options for the input audio
signal(s).
Mute
will mute all channels controlled by the respective column.
Input Gain (dB)
sets the gain [-80 … +20]
Input HPF (Hz)
high pass filter (6dB/oct) cut off frequency [OFF, 2, 20, 40, 80, 120]
Input LPF (kHz)
low pass filter (6dB/oct) cut off frequency [OFF, 15, 20, 22]
Input Delay (ms)
[1 … 2000]
Web GUI – AUDIO PROCESSOR – Fail Over
Fail Over – Set the conditions for detecting loss of main audio in order to trigger switching to the secondary
source.
For the program input 1L/1R, the source for the fail over circuit can be the second program input
(input 2L/R). The Mode switch will select the respective signal path.
Fail Over 1L/1R
MODE
The Fail Over output can be permanently connected to :
its program input 1L/1R
the second program input 2L/2R
or may be set to AUTO