Jung Observer 220 Скачать руководство пользователя страница 1

Observer 220 

Observer 220 

Art.-No.: W 220 WW

Operationsmanual 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Device is not suitable for disconnection from supply voltage. 

Danger of electric shock. Always disconnect before carrying out work on the devise or 
load. At the same time, take into account all circuit breakers that supply dangerous 
voltage to the device or load. 

Do not press on the sensor window. Device can be damaged. 

The device is not suitable for use as a burglar alarm or other alarm. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

picture 1: Page view 

(1)  Connection box 
(2)  Sensor head 
(3)  Sensor window 

1/15 

32536423 
J:0082536423 

26.07.2010 

Содержание Observer 220

Страница 1: ...voltage Danger of electric shock Always disconnect before carrying out work on the devise or load At the same time take into account all circuit breakers that supply dangerous voltage to the device or...

Страница 2: ...n Protected against spray water Follow up time sensitivity and brightness value settable Test operation for checking the detection area Switch light on or off for 4 hours Short time operation to contr...

Страница 3: ...threshold for 2 minutes 4 Operation Notes on setting the operating mode The operating mode can be changed using an installation button NC contact Depending on the desired operating mode the installati...

Страница 4: ...tector The three adjusters can be used to set the run on time the brightness the sensitivity and a short time operation picture 4 Set follow up time The light remains switched on for this time after t...

Страница 5: ...on In short time operation when motion is detected a pulse of 0 5 seconds is generated that can be used e g to activate a bell This operating mode functions independently of the brightness picture 5 o...

Страница 6: ...ns of self adhesive cover plate elements The cover plate elements picture 7 are pre punched for all 5 cover layers and can be trimmed to the desired angle Do not interchange the right side and left si...

Страница 7: ...r plate elements to the left side of the sensor window picture 8 i Due to the complex structure of the motion detector sharp delimitation of the hidden area is not possible in all cases Example 2 Hidi...

Страница 8: ...al connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the corresponding circuit breakers Cover u...

Страница 9: ...nsor head Low temperature difference Installation height less than 2 4 m Effects of weather e g rain or snow The range is increased in the case of The land slopes downwards away from the motion detect...

Страница 10: ...out condensation water holes 10 picture 14 Exception installation in dusty rooms The connection box has 6 cable entries 11 that are provided with moulded in rubber sheaths The supply and power cables...

Страница 11: ...ter screw holes 12 picture 14 Connecting and installing the motion detector picture 15 Terminals The connecting cables are preassembled with screwless terminals brown BN relay lamp cable black BK L ex...

Страница 12: ...g switched on on the power cable and also switch on The motion detector with the longest run on time determines the switch on time i All motion detectors connected in parallel must be operated on the...

Страница 13: ...rightness threshold and sensitivity see Operation 6 Appendix 6 1 Technical data Rated voltage AC 230 240 V Power consumption approx 1 1 W Ambient temperature 20 55 C Protection rating IP 55 Circuit br...

Страница 14: ...e g ventilation cooling light bulbs trees and bushes Align sensor head stick cover plate elements on sensor window or reduce sensitivity sens Cause 2 Operating mode Light on for 4 hours is switched o...

Страница 15: ...GMBH CO KG Volmestra e 1 D 58579 Schalksm hle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 1 89 E mail mail info jung de Internet www jung de www jung katalog de 15 15 32536423 J 0082536423 26 07 201...

Отзывы: