Motion detector mini basic

(3)

Terminal

(4)

Motion detector

(5)

Design ring

The environment in the suspended ceiling must be dry.

Max. thickness of the suspended ceiling approx. 25 mm. Installation depth min. 35 mm. Dis-
tance between concrete ceiling and suspended ceiling min. 20 mm (Figure 2).

Create ceiling cut-out Ø 44...45 mm(Figure 2).

Connecting the device

Figure 3: Clampable conductor cross-section

Recommended line J-Y(St)Y 2×2×0.8 (2 wire pairs, conductor diameter 0.8 mm this corres-
ponds to a conductor cross-section of 0.5 mm²).

For the cable length, also observe the information in the instructions for the device to be con-
nected.

Use the unchoked output of a KNX power supply or power supply unit with safety extra-
low voltage as power supply.

Connect the connection cable to device connection terminal (3) (Figure 2).

Connection in general

Terminal assignment of motion detector

Terminal

Connection

DC24V +

Power

DC24V –

Power supply GND

A+

Switching

A–

Switching output –

Figure 4: Connection in general

For connection diagrams for various KNX devices, see accessories

Figure 5: Connection to Multi station

3 / 6

82403103

29.09.2020

J0082403103