4-/8-channel switching actuator 16A 

4-/8-channel switching actuator 16A / C-load 

 

Art.-Nr.: 230x.16 REGHM, 230x.16REGCHM 

Operation Instructions  
4-/8-channel switching actuator 16A  
4-/8-channel switching actuator 16A / 

C-load with current detection

 

 

 

1. Safety instructions 

Electrical equipment must be installed and fitted by qualified 
electricians only. Observe the current accident prevention 
regulations. Failure to observe the instructions may cause damage 
to the device and result in fire or other hazards. The device is not 
suited for safe disconnection of the mains supply. Do not connect 
mains voltage consumers together with SELV/ PELV consumers to 
the same switching actuator. Do not connect three-phase AC 
motors to the actuator. The current detection and load monitoring 
functions must not be used for safety-related applications, e.g. 
overload detection. These operating instructions are part of the 
product and must be left with the final customer. 

2.  System information 

This device is a product of the KNX-system and complies with KNX 
directives. Technical knowledge obtained in KNX training courses is a 
prerequisite to proper understanding. The functionality of this device 
depends on the software. Detailed information on loadable software and  

Stand: Mai-07   

825 603 03

 

Содержание KNX 230 .16 REGHM Series

Страница 1: ...e disconnection of the mains supply Do not connect mains voltage consumers together with SELV PELV consumers to the same switching actuator Do not connect three phase AC motors to the actuator The cur...

Страница 2: ...nel and 8 channel switching actuators for C loads Switching of capacitive loads with resulting higher inrush currents 3 1 Product features Bus independent manual switching of relays Operation as n c o...

Страница 3: ...mming button and LED 3 KNX terminal 4 relay output terminals Slide switching position indicator 1 into the ON position The relay contact is closed and the consumer is activated Slide switching positio...

Страница 4: ...onnecting terminals must be at the top 5 2 Connection of the device Observe the admissible loads L Do not connect three phase AC motors to the actuator L On delivery the switching state is undefined S...

Страница 5: ...onnecting terminal slide on the protective cap Lead out the bus line at the rear of the device Slide the cap over the bus terminal Fig 3 A until it is heard to engage 5 4 Removing the cap Press the si...

Страница 6: ...C 45 C Storage temperature 25 C 70 C Total dissipated power 4 channel switching actuators max 4 W 8 channel switching actuators max 8 W Mounting width 4 channel switching actuators 72 mm 4 modules 8...

Страница 7: ...KNX 4 8 channel switching actuator 16A 4 8 channel switching actuator 16 A C load Art Nr 230x 16 REGHM 230x 16REGCHM 8 Switching capacitiy 7...

Страница 8: ...d rectified 11 Guarantee Our products are under guarantee within the scope of the statutory provisions Please return the unit postage paid to our central service department giving a brief description...

Отзывы: