Switch actuators flush mounted – 1gang 16A, 2gang 6A 

Switch actuator, 1-gang 

Art. No. 2131.16 UP

Switch actuator, 2-gang 

Art. No. 2132.6 UP

Operating instructions 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock on the KNX installation. Do not connect any external voltage to 
the inputs. Doing so may damage the device(s), and the SELV potential on the KNX bus 
line will no longer be available. 

Danger of electric shock. Before working on the device or before exchanging light bulbs, 
disconnect mains voltage and switch off circuit breakers. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

Figure 1: Switch actuator 1gang 

1/6 

82553923 
J:0082553923 

18.09.2012 

Содержание KNX 2131.16 UP

Страница 1: ...e and other hazards Danger of electric shock on the KNX installation Do not connect any external voltage to the inputs Doing so may damage the device s and the SELV potential on the KNX bus line will no longer be available Danger of electric shock Before working on the device or before exchanging light bulbs disconnect mains voltage and switch off circuit breakers These instructions are an integra...

Страница 2: ...r 1gang BN brown connection external conductor L output L Switch actuator 2gang BK black connection external conductor L PK pink connection output L 1 GY grey connection output L 2 Figure 3 Connection assignment of control cable RD red KNX BK black KNX GN green input 1 YE yellow input 2 WH white COM input 1 BN brown COM input 2 2 6 82553923 J 0082553923 18 09 2012 Switch actuators flush mounted 1g...

Страница 3: ...An additional function for each output logical forced position or time function Time functions switch on delay switch off delay staircase lighting timer Supply via bus no additional power supply necessary i Switch actuator 2gang When activated by a central telegram the relay outputs of the actuator switch with a slight time delay 4 Information for electrically skilled persons 4 1 Fitting and elect...

Страница 4: ...wer dissipation o Connect the load Use the supplied sprung screwless terminals Flexible cable ends must be tin plated o Connect the device to KNX o If necessary connect potential free contacts to the inputs figure 3 o Install the device in the appliance box Function of Inputs 1 and 2 in the as delivered state Input contact Switch actuator 1gang Switch actuator 2gang 1 close Toggle Switch over outp...

Страница 5: ...Inductive transformers 1000 VA Tronic transformers 1000 W Control cable and inputs Control cable preterminated YY6x0 6 Input type Potential free Total length of extension unit cable max 5 m Poll voltage extension inputs approx 19 V Dimensions Ø H 53 28 mm Ø Centre hole 7 5 mm Connection of outputs Connection mode Screwless terminal enclosed KNX KNX medium TP 1 Commissioning mode S mode Rated volta...

Страница 6: ... V SELV Connection type for bus Connection terminal Power consumption KNX typical 150 mW 5 2 Warranty We reserve the right to make technical and formal changes to the product in the interest of technical progress We provide a warranty as provided for by law Please send the unit postage free with a description of the defect to our central customer service office ALBRECHT JUNG GMBH CO KG Volmestraße...

Отзывы: