LB management 

eNet radio centre plate

Parameters

Setting options, Basic
setting

Explanations

Deactivate twi-
light switching
state

On, Off 
Basic setting: Off

Defines the behaviour of the output on deactivat-
ing the twilight function. Only visible when the pri-
ority for the twilight function is 0.

Invert switching
output

On, Off 
Basic setting: Off

Inverts the switching output from NO contact
function (factory setting) to NC contact function

Minimum switch-
ing repeat time

100 ms ... 10 sec 
Basic setting: 100 ms

Limits the switching speed of the device by in-
creasing the value, in order to protect the load,
for example. Only when the set time has elapsed
is switching possible again. The last command
during the blocking time is executed after a delay.
The switching repeat time starts after each
switching operation.

Channel settings "dimming"

Parameters

Setting options, Basic
setting

Explanations

Switch-on bright-
ness

1...100 % 
Basic setting: 100 %

During brief operation, the output switches on at
the set switch-on brightness. Note: If the value is
above the set maximum brightness or below the
minimum brightness, then the system will switch
to the appropriate limit value.

Minimum bright-
ness

1...67 % 
Basic setting: 5 %

Specifies the minimum settable brightness. Note:
If parameters or scene values are set to a level
lower than the minimum brightness, then the sys-
tem will dim to minimum brightness.

Maximum bright-
ness

75...100 % 
Basic setting: 100 %

Specifies the maximum settable brightness. Note:
If parameters or scene values are set to a level
higher than the maximum brightness, then the
system will dim to maximum brightness.

Dimming adjust-
ment time

1…60 s 
Basic setting: 4 s

Time from minimum brightness until reaching
maximum brightness (dimming speed).

Switch-on delay

0 s … 24 h 
Basic setting: 0 s

The load switches on after a delay. Repeated
switch-on commands restart the delay time. If the
load has not yet been switched on due to the
delay when a switch-off command comes, then
the load will remain off.

Switch-off delay

0 s … 24 h 
Basic setting: 0 s

The load switches off after a delay. Repeated
switch-off commands restart the delay time. If the
load has not yet been switched off due to the
delay when a switch-on command comes, then
the load will remain on.

Dim up ramp

0 s … 24 h 
Basic setting: 0 s

Time between switch-on and reaching switch-on
brightness. The light is switched on at minimum
brightness and then dimmed to the switch-on
brightness. Only applies to switch-on with trans-
mitters (short operation). If scenes are recalled or
switching uses logic modules, the switch-on
brightness is approached using so-called soft
dimming (not configurable).

14 / 29

32597903

07.08.2019

J0082597903

Содержание FM 1701 Series

Страница 1: ...tion takes place via a non exclusively available transmission path and is therefore not suitable for safety related applications such as emergency stop and emergency call These instructions are an int...

Страница 2: ...ventilation position of the blind shutter can be saved Functions in combination with light insert Scene operation possible Switch on brightness can be saved permanently when combined with flush mount...

Страница 3: ...press button 3b within the next 4 seconds The running time is saved The blind shutter moves back to the upper end position The change over time of the slats for the venetian blind and time fabric str...

Страница 4: ...y group status Polling sum status Press buttons 3a and 3b for 1 to 4 seconds If there is no status message from at least one remote actuator a transmission error is signaled Status LED flashes red qui...

Страница 5: ...sconnected and parameters are reset to the default setting The connections in the radio transmitters and radio actuators are preserved and must be deleted separately Load is switched off Press buttons...

Страница 6: ...ccessful All the memory locations in the attachment or radio transmitter are occupied Connecting attachment to radio actuator Up to 10 radio actuators can be connected to a transmitter in a single ste...

Страница 7: ...s a channel button Unused The channel is not displayed in the eNet SMART HOME app and is disabled for use in the com missioning interface Actuator channel function Switch insert Dimming insert Extensi...

Страница 8: ...ace Operating mode Dimming Normal operation Continuous on Continuous off Basic setting Normal operation Normal operation The insert can be operated with radio transmit ters via an extension or directl...

Страница 9: ...or use in the com missioning interface Venetian blind operating mode Roller shutter Venetian blind Awning Basic setting Roller shutter Roller shutter A shutter is controlled The channel is integrated...

Страница 10: ...ion in the eNet SMART HOME app The fan channel switches on and off with a delay depending on the set parameters Switching fan The switching channel is not integrated in any central function The fan ch...

Страница 11: ...delay Repeated switch off commands restart the delay time If the load has not yet been switched off due to the delay when a switch on command comes then the load will remain on In Flashing operating...

Страница 12: ...o grammed to apply the change Extended channel settings switching Parameters Setting options Basic setting Explanations Operating mode Switching operation Push button operation Flashing Continuous on...

Страница 13: ...our of the output on activating the forced operation Deactivate forced operation switch ing state On Off Basic setting Off Defines the behaviour of the output on deactivat ing the forced operation Onl...

Страница 14: ...brightness Note If parameters or scene values are set to a level lower than the minimum brightness then the sys tem will dim to minimum brightness Maximum bright ness 75 100 Basic setting 100 Specifie...

Страница 15: ...ured 0 s in addition to motion detector commands all switching or dimming commands also lead to switching on for the duration of the run on time If no run on time is configured 0 s all switch ing or d...

Страница 16: ...100 Basic setting 100 Brightness value set by the output after voltage return mains voltage The parameter Beha viour after voltage return must be set to Con figured brightness Note If the value is abo...

Страница 17: ...ting 0 Defines the behaviour of the output on activating the wind alarm Deactivate wind alarm brightness value 0 100 Basic setting 0 Defines the behaviour of the output on deactivat ing the wind alarm...

Страница 18: ...e delay when a switch on command comes then the load will remain on Extended channel settings 3 wire extension Parameters Setting options Basic setting Explanations Operating mode Normal operation Con...

Страница 19: ...essential if scene or position movements are to occur Slat change over time fabric stretching time 0 ms 10 sec 300 ms 10 s Basic setting 0 ms 300 ms Absolute time for changing over Venetian blind sla...

Страница 20: ...Basic setting 0 Defines the behaviour of the output on deactivat ing the lock out protection Only visible when the priority for the lock out protection is 0 Deacitvate lock out protection slat positio...

Страница 21: ...tection slat posi tion 0 100 Basic setting 100 Defines the slat position of the output on activat ing the sun protection Only visible when the Venetian blind operating mode is set Deactivate sun prot...

Страница 22: ...n time entered here If no run on time is entered here the default run on time of 2 minutes is applied Use run on time On Off Basic setting Off On If a run on time is configured 0 s in addition to moti...

Страница 23: ...ttings Switching fan Parameters Setting options Basic setting Explanations Operating mode Switching operation Push button operation Flashing Continuous on Continuous off Basic setting Switching operat...

Страница 24: ...riority wind alarm 0 4 Basic setting 3 Specifies the priority for recalling and removing a scene of type Wind alarm for the channel Activate wind alarm switching state On Off Basic setting Off Defines...

Страница 25: ...etting 0 s If a run on time is entered and the Use run on time parameter is activated the actuator no longer remains permanently switched on but only for the duration of the run on time entered here o...

Страница 26: ...n using the button Behaviour on voltage return On Off Last value Basic setting Off Defines the behaviour of the output after voltage return Timer behaviour voltage return Off Restart Basic setting Off...

Страница 27: ...o tection 0 4 Basic setting 0 Specifies the priority for recalling and removing a scene of type Sun protection for the channel Activate sun pro tection switching state On Off Basic setting On Defines...

Страница 28: ...the attachment Operating hours Display of the operating hours since the last restart in the Settings window Venetian blind Display value Explanations Position value venetian blind The position value...

Страница 29: ...m type art no FM 1701 meets the directive 2014 53 EU You can find the full article number on the device The com plete text of the EU Declaration of Conformity is available under the Internet address w...

Отзывы: