Jung eNet FM AS 16 REG Скачать руководство пользователя страница 6

6 Appendix

6.1 Technical data

Rated voltage

AC 230 V ~

Mains frequency

50 / 60 Hz

Ambient temperature

-5 ... +45 °C

Switching current for AC 230 V ~
Ohmic

16 A

For switching current >10A connecting cable 2.5mm²
Fluorescent lamps

4 AX

Minimum switching current AC

100 mA

Contact type

µ

Standby power

max. 0.2 W

Connected load
Incandescent lamps

2300 W

HV halogen lamps

2000 W

Tronic transformers

1500 W

HV-LED lamps

typical 500 W

Compact fl lamp.

typical 500 W

Inductive transformers

1000 VA

Fluorescent lamps, uncompensated

920 VA

Capacitive load

690 VA (560 µF)

Connection of load terminals
single stranded

1.5 ... 4 mm²

finely stranded without conductor sleeve

0.75 ... 4 mm²

Finely stranded with conductor sleeve

0.5 ... 2.5 mm²

Fitting width

36 mm / 2 modules

Bus line
Rated voltage

DC 12 V SELV

Current consumption

max. 20 mA

Connection, Bus

Connection terminal

Cable length

max. 3 m

6.2 Parameter list

Settings window
Device settings

Parameters

Setting options, Basic
setting

Explanations

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for all device channels. In the
"Off" setting, the device
cannot be reset to the factory
setting. 

Settings, channel

Parameters

Setting options, Basic
setting

Explanations

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for the device channel. In the
"Off" setting, the device
cannot be reset to the factory
setting.

6/11

82581713
J:0082581713

11.03.2014

eNet

Radio switch actuator for rail mounting, 1-channel

Содержание eNet FM AS 16 REG

Страница 1: ...ns and standards which apply for SELV circuits Danger of electric shock Device is not suitable for disconnection from supply voltage Fire hazard Operation exclusively with the power supplies listed un...

Страница 2: ...0 seconds Can be set with eNet server Flash function Run on time Switch on delay switch off delay Operation as NO or NC contacts Switch off warning Minimum switching repeat time Operation locks Contin...

Страница 3: ...on DIN rail Output terminals must be at the top Connect bus line Figure 2 Connection diagram of bus line Labelling Colour Connection DC GY dark grey Power supply DC RD red Power supply Bus WH white Da...

Страница 4: ...eter set with eNet server M Operating mode buttons K Switching mode of operation If the operating mode switch is turned from the position PC to another operating mode the parameters are set to the def...

Страница 5: ...place i Scene buttons must be connected separately Disconnecting connection to a radio transmitter o Carry out the same steps as when connecting see Connecting actuator to radio transmitters The statu...

Страница 6: ...ctor sleeve 0 75 4 mm Finely stranded with conductor sleeve 0 5 2 5 mm Fitting width 36 mm 2 modules Bus line Rated voltage DC 12 V SELV Current consumption max 20 mA Connection Bus Connection termina...

Страница 7: ...rameter Switch off delay is used for the pulse time and the parameter Switch on delay for the pause time Continuous on The output switches to continuously On All operations of radio transmitters and t...

Страница 8: ...e set time apply to operation using radio transmitters The relay is switched immediately when the Prog button is pressed Run on time 0 s 24 h Basic setting 0 s As soon as a run on time has been entere...

Страница 9: ...nnel Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Priority wind alarm 0 4 Basic setting 3 Specifies the prio...

Страница 10: ...ching repeat time starts after each switching operation Operating hours 0 65535 Basic setting Current value The time is counted during which the load is physically switched on relay contact closed Thi...

Страница 11: ...of technical progress We provide a warranty as provided for by law Please send the unit postage free with a description of the defect to our central customer service office ALBRECHT JUNG GMBH CO KG V...