Jung 5201 HYG Series Скачать руководство пользователя страница 3

 

Temperature Management 

Hygrostat  

 Ref.-no.: 

..5201 

HYG.. 

 

3.2. Product features 

  Measurement of room temperature and air humidity to determine 

the optimal content of moisture in the air 

  Control of heating and ventilation appliances for the removal of 

moisture in rooms 

  Manual control range approx. 20…95 % or fixed value of 60 % 

relative humidity 

  Control knob for manual adjustment of the setpoint 

  Modes of operation: automatic, manual, party, standby 

 Status 

LED 

  Time-controlled continuous operation 

3.3. Automatic mode 

When the air humidity exceeds the preset value, the hygrostat activates 
the connected dehumidification appliance: 

 LED   yellow: 

off

, LED 

 green: 

on

, LED 

 red: 

off

 

When the air humidity is lower than the preset value, the hygrostat 
deactivates the connected appliance: 

 LED   yellow: 

off

, LED 

 green: 

off

, LED 

 red: 

off

 

After one hour of continuous operation, the hygrostat switches off the 
appliance for 4 hours: 

 LED   yellow: 

off

, LED 

 green: 

off

, LED 

 red: 

on

 

L

  If the content of water in the ambient air is very high, a 

dehumidification by means of a fan is not possible.  

3.4. Manual mode 

Fan operation is activated manually for abt. one hour. 

 LED   yellow: 

on

, LED 

 green: 

on

, LED 

 red: 

off

 

3.5. Party mode 

Fan operation is activated manually for abt. six hours. 

 LED   yellow: 

on

, LED 

 green: 

on

, LED 

 red: 

flashing

 

3.6. Standby mode 

Fan operation is deactivated manually for abt. four hours. 

 LED   yellow: 

on

, LED 

 green: 

off

, LED 

 red: 

on

 

 

Содержание 5201 HYG Series

Страница 1: ...Party mode 3 3 6 Standby mode 3 4 Operation 4 4 1 Setting the humiditiy manually 4 4 2 Dehumidifying the ambient air manually 4 4 3 Activating the party mode 4 4 4 Activating the standby mode 4 4 5 S...

Страница 2: ...be operated if additional protective measures are taken The applicable Building Regulations for hearth and fireplace installations must be observed These operating instructions are part of the produc...

Страница 3: ...umidification appliance LED yellow off LED green on LED red off When the air humidity is lower than the preset value the hygrostat deactivates the connected appliance LED yellow off LED green off LED...

Страница 4: ...e must be in the automatic mode of operation Depress the mode of operation selector briefly The relay is switched on for abt one hour independent of the degree of humidity in the room LED yellow on LE...

Страница 5: ...y temporarily measure higher humidity values Information for qualified electricians DANGER Electric shock in case of accidental contact with live parts Electric shocks can be fatal Before working on t...

Страница 6: ...l characteristics For installation installation in bathrooms laundry rooms etc observe the safety distances in acc with IEC 60364 7 701 Fitting height approx 1 5 m Installation in a flush mounting box...

Страница 7: ...ll LED s blinking Device installed on wrong insert e g blind shutter insert Install the device on a suitable insert 6 3 Guarantee Our products are under guarantee within the scope of the statutory pro...

Отзывы: