Product characteristics 

Connection of multiple power extensions to one dimmer possible 

Operation using upstream dimmer 

Lamp-beneficial soft start 

Electronic short circuit protection with permanent switch-off 

Electronic over-temperature protection 

Switch-on delay of lamps on power extension of 1 - 2 s 

Brightness differences between the lighting at the dimmer and the lightning at the power 
extension are possible. 

4 Information for qualified electricians 

4.1 Fitting and electrical connection 

DANGER! 
Electrical shock when live parts are touched. 
Electrical shocks can be fatal. 
Before carrying out work on the device or load, disengage all the 
corresponding circuit breakers. Cover up live parts in the working environment. 

Fitting and connecting the power extension 

Use the same external conductor for dimmers and power extensions. Do not swap L and N 
on the power extension. Otherwise, there is the risk of malfunction. 

picture 2 

(1)  Power extension 
(4)  Dimmer 

Fit the power extension. 

Minimum diameter of ceiling opening for installation in false ceilings: 63 mm. 

Connect the power extension according to the connection diagram (picture 2). 

In the case of lighting systems with an output of over 3500 W/VA, the installation must be 
distributed across two miniature circuit breakers with the same external conductor. 

If multiple circuit breakers supply dangerous voltages to the device or load, couple the 
circuit breaker to ensure tripping. 

2/4 

82540013 
J:0082540013 

11.08.2010 

Light Management  

Amplifier for conventional dimmers, built-in 