Switch actuator 

Switch actuator, 2-gang 

Art. No. 2302.16 REG HM

Switch actuator, 4-gang 

Art. No. 2304.16 REG HM

Switch actuator, 8-gang 

Art. No. 2308.16 REG HM

Switch actuator, 4-gang, C-load 

Art. No. 2304.16 REG C HM

Switch actuator, 8-gang, C-load 

Art. No. 2308.16 REG C HM

Operating instructions 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Device is not suitable for disconnection from supply voltage. 

Danger of electric shock on the SELV/PELV installation. Do not connect loads for mains 
voltage and SELV/PELV together on a single switch actuator. 

Do not connect any three-phase motors. Device can be damaged. 

Do not use the current detection and load monitoring functions for safety-related 
applications e.g. overload detection.  

For the outputs, use circuit breakers for the respective rated current. Device can be 
damaged. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

Figure 1: View of switch actuator 4gang  

(1)  Slide switch/Status indication 
(2)  Programming button and LEDs 
(3)  KNX connection 
(4)  Connection of relay outputs 

1/8 

82560323 
J:0082560323 

03.09.2013 

Содержание 2302.16 REG HM

Страница 1: ...isconnection from supply voltage Danger of electric shock on the SELV PELV installation Do not connect loads for mains voltage and SELV PELV together on a single switch actuator Do not connect any thr...

Страница 2: ...ns switch on delay and run on time staircase lighting timer with pre warning function Integration into light scenes Operating hours meter configurable via bus Input monitoring for cyclical updating wi...

Страница 3: ...OFF position o Connect device as shown in the connection example figure 2 o Connect bus line with bus connection terminal i Various external conductors can be connected i Devices for C loads use non...

Страница 4: ...Press the cover to the side and pull it off figure 4 5 2 Commissioning Load the address and the application software o Switch on the bus voltage o Assign physical address o Load the application softw...

Страница 5: ...REG C HM 0 25 16 A Art No 2308 16 REG C HM 0 25 16 A Accuracy 1 A Art No 2302 16 REG HM Art No 2304 16 REG HM Art No 2308 16 REG HM Art No 2304 16 REG C HM 100 mA Art No 2308 16 REG C HM 100 mA Accur...

Страница 6: ...Art No 2308 16 REG HM 1200 VA Art No 2304 16 REG C HM 2000 VA Art No 2308 16 REG C HM 2000 VA LV halogen lamps with Tronic transformer Art No 2302 16 REG HM 1500 W Art No 2304 16 REG HM 1500 W Art No...

Страница 7: ...16 REG C HM 144 mm 8 modules Weight Art No 2302 16 REG HM approx 170 g Art No 2304 16 REG HM approx 220 g Art No 2308 16 REG HM approx 400 g Art No 2304 16 REG C HM approx 270 g Art No 2308 16 REG C H...

Страница 8: ...G Volmestra e 1 58579 Schalksm hle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 2 04 kundencenter jung de www jung de Service Center Kupferstr 17 19 44532 L nen Germany 8 8 82560323 J 0082560323 03 0...

Отзывы: