Jung 1701SE Скачать руководство пользователя страница 6

Image 3: Connection diagram in combination with a room thermostat cover or KNX

RF push-button

(6)

Switching contact for switching to cooling mode

(7)

Electric underfloor heating system (max. 16 A) or electrothermal valve
drives

If 230 V is applied to extension input 1, cooling mode is active.

5

Technical data

Rated voltage

AC 230 V ~

Mains frequency

50 / 60 Hz

Standby load depending on the cover

approx. 0.1 ... 0.5 W

Switching current at 35 °C

Ohmic

16 A (AC1)

Motors

6 A

Connected load

Incandescent lamps

2300 W

HV halogen lamps

2300 W

Electronic transformers

1500 W

Inductive transformers

1000 VA

HV-LED lamps

typ. 400 W

Compact fluorescent lamps

typ. 500 W

Fluorescent lamps, uncompensated

1200 VA

Capacitive load

920 VA (115 μF)

Relay switch insert 1-channel

6 / 7

82597453

19.10.2022

J0082597453

Содержание 1701SE

Страница 1: ...Relay switch insert 1 channel Art no 1701SE 19 10 2022 82597453 J0082597453 ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencente...

Страница 2: ...ontents 1 Safety instructions 3 2 Intended use 3 3 Operation 3 4 Information for electrically skilled persons 4 5 Technical data 6 6 Warranty 7 2 7 82597453 19 10 2022 J0082597453 Relay switch insert...

Страница 3: ...suitable cover from the systems LB management JUNG HOME eNet and KNX RF Mounting in appliance box with dimensions according to DIN 49073 Product characteristics Connection of extensions possible Sett...

Страница 4: ...on diagram with optional extensions Image 2 Terminal specific cable cross section Connect the switch insert 2 according to the connection diagram see figure 1 Note clampable cable cross sections see f...

Страница 5: ...LED lights up in the colour of the set run on time see table Release the TEST button 1 briefly and then press it repeatedly until the LED lights up in the colour of the desired time The set time is au...

Страница 6: ...echnical data Rated voltage AC 230 V Mains frequency 50 60 Hz Standby load depending on the cover approx 0 1 0 5 W Switching current at 35 C Ohmic 16 A AC1 Motors 6 A Connected load Incandescent lamps...

Страница 7: ...70 C Number of extension units 2 wire push button unlimited 3 wire rotary extension 10 6 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade ALBRECHT...

Отзывы: