1
Safety instructions
Electrical devices may only be mounted and connected by electrically skilled
persons.
Serious injuries, fire or property damage possible. Please read and follow manual
fully.
Danger of electric shock. Always disconnect before carrying out work on the device
or load. In so doing, take all the circuit breakers into account, which support danger-
ous voltages to the device and or load.
This manual is an integral part of the product, and must remain with the end cus-
tomer.
2
Intended use
–
Switching of lighting and motors
–
Control of electric underfloor heating systems and electrothermal valve drives
in combination with a room thermostat cover or KNX RF push-button
–
Operation with suitable cover from the systems LB management, JUNG
HOME, eNet and KNX RF
–
Mounting in appliance box with dimensions according to DIN 49073
Product characteristics
–
Connection of extensions possible
–
Settable time functions
3
Operation
These instructions describe operation with a LB Management push-button 1-gang.
Operation with a different cover is described in the instructions for the cover in ques-
tion. The operation on the main device and the 2-wire extension is identical.
Switching the load
■
Press the operating cover.
The load switches on or off.
Time function
Different times can be set for the automatic switching-off of the load. The time func-
tion starts as soon as the output is switched on. To terminate the time function pre-
maturely, switch off the output manually.
The time function cannot be restarted by pressing again.
Relay switch insert 1-channel
3 / 7
82597453
19.10.2022
J0082597453