background image

1

Safety instructions

Electrical devices may only be mounted and connected by electrically skilled
persons.

Serious injuries, fire or property damage possible. Please read and follow manual
fully.

Danger of electric shock. Always disconnect before carrying out work on the device
or load. In so doing, take all the circuit breakers into account, which support danger-
ous voltages to the device and or load.

This manual is an integral part of the product, and must remain with the end cus-
tomer.

2

Intended use

Switching of lighting and motors

Control of electric underfloor heating systems and electrothermal valve drives
in combination with a room thermostat cover or KNX RF push-button

Operation with suitable cover from the systems LB management, JUNG
HOME, eNet and KNX RF

Mounting in appliance box with dimensions according to DIN 49073

Product characteristics

Connection of extensions possible

Settable time functions

3

Operation

These instructions describe operation with a LB Management push-button 1-gang.
Operation with a different cover is described in the instructions for the cover in ques-
tion. The operation on the main device and the 2-wire extension is identical.

Switching the load

Press the operating cover.

The load switches on or off.

Time function

Different times can be set for the automatic switching-off of the load. The time func-
tion starts as soon as the output is switched on. To terminate the time function pre-
maturely, switch off the output manually.

The time function cannot be restarted by pressing again.

Relay switch insert 1-channel

3 / 7

82597453

19.10.2022

J0082597453

Содержание 1701SE

Страница 1: ...Relay switch insert 1 channel Art no 1701SE 19 10 2022 82597453 J0082597453 ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencente...

Страница 2: ...ontents 1 Safety instructions 3 2 Intended use 3 3 Operation 3 4 Information for electrically skilled persons 4 5 Technical data 6 6 Warranty 7 2 7 82597453 19 10 2022 J0082597453 Relay switch insert...

Страница 3: ...suitable cover from the systems LB management JUNG HOME eNet and KNX RF Mounting in appliance box with dimensions according to DIN 49073 Product characteristics Connection of extensions possible Sett...

Страница 4: ...on diagram with optional extensions Image 2 Terminal specific cable cross section Connect the switch insert 2 according to the connection diagram see figure 1 Note clampable cable cross sections see f...

Страница 5: ...LED lights up in the colour of the set run on time see table Release the TEST button 1 briefly and then press it repeatedly until the LED lights up in the colour of the desired time The set time is au...

Страница 6: ...echnical data Rated voltage AC 230 V Mains frequency 50 60 Hz Standby load depending on the cover approx 0 1 0 5 W Switching current at 35 C Ohmic 16 A AC1 Motors 6 A Connected load Incandescent lamps...

Страница 7: ...70 C Number of extension units 2 wire push button unlimited 3 wire rotary extension 10 6 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade ALBRECHT...

Отзывы: