background image

17

Screen Display

Operating Instructions

Displayed State

Sound and

backlight

color

Error information & low battery

The ambient temperature is higher

than 40.0ºC (104.0ºF) or lower than

10.0ºC (50.0ºF).

A long beeps,the

backlight is red.

An error occurs when data is being

read from or written to the memory,

or the temperature correction is not

complete.

A long beeps,the

backlight is red.

When the battery voltage is lower

than 2.5V ± 0.1V, the low battery

symbol will appear on the display.

Please replace the batteries.

Silent

Measuring Ear Temperature

1. When using the thermometer for the first time, move the battery’s

insulating piece away.

2. Take the probe cover off from the thermometer before measuring the

Содержание JPD-FR410

Страница 1: ...JPD FR410 Infrared Thermometer Instruction Manual Shenzhen Jumper Medical Equipment Co Ltd Manual Version 1 0 Date of Issue 2018 08 0482...

Страница 2: ...ithout the prior consent of Shenzhen Jumper Medical Equipment Co Ltd All statements information and recommendations in this document are provided AS IS without warranties guarantees or representations...

Страница 3: ...cklight instructions 10 Display and Operating Instructions 11 Measuring Ear Temperature 17 Measuring Forehead Temperature 19 Measuring Object Temperature 20 Replacing Batteries 21 Cleaning and Disinfe...

Страница 4: ...ealer or contact Jumper directly You will need the following information when making your claim device model serial number purchase date and your contact information and address Package Contents No Na...

Страница 5: ...20 minutes after you do physical exercises or get excited Clean the thermometer probe after each use Do not use the thermometer on newborns or for continuous temperature monitoring purposes Do not us...

Страница 6: ...than 10 C 50 F which is beyond the operating temperature range of the thermometer Risk of pollution The user is recommended to send the overdue thermometer to local garbage disposal site or send it ba...

Страница 7: ...ttery may explode Do not disassemble the thermometer or attempt to repair it Otherwise the thermometer may be damaged permanently Do not take temperature measurements on body parts other than forehead...

Страница 8: ...e MDD93 42 EEC requirements Waste electrical materials should be sent to a dedicated collection point for recycling IPX0 Degree of protection against the Ingress of water Warning A personal injury or...

Страница 9: ...8 0 C 97 9 F 100 4 F The normal body temperature range slightly varies with age and gender Generally newborns or children have higher body temperature than adults and adults have higher body temperatu...

Страница 10: ...s of a shell an LCD a measure button a beeper an infrared temperature sensor and a Microprocessor 3 Operating principle The infrared temperature sensor collects infrared energy emitted by the eardrum...

Страница 11: ...nd measurement 04 High accuracy Advanced infrared temperature sensor with high sensitivity High accuracy with automatic temperature calibration 05 Diverse functions 20 reading recalled Fever alert Swi...

Страница 12: ...off the cover when measuring the ear temperature 6 Probe cover put the cover on when measuring the forehead temperature 7 Unit switch button 8 Memory button Sound switch 9 Battery cover Display descr...

Страница 13: ...ect temperature 0 100 32 0 212 A long beep Orange Note When the forehead and the ear temperature is between 35 0 C 95 0 and 37 5 C 99 5 there will be a long beep and a red backlight This indicates tha...

Страница 14: ...nd to power on the thermometer Press the Mode button the thermometer enters the Ear mode The symbol is displayed on the screen Switch to the adult or child measurement mode by dialing the side adult c...

Страница 15: ...hermometer enters the Forehead mode The Head symbol is displayed on the screen Switch to the adult or child measurement mode by dialing the side adult child switcher according to your measurement need...

Страница 16: ...d on the screen See the table in the Sounds and backlight color instructions section Out of the measuring range display In Ear mode a temperature reading of more than 42 0 C 107 6 F In Forehead mode a...

Страница 17: ...be shown followed by the recorded reading Press the Memory button again for the next recorded data 2 will be shown followed by the recorded reading A maximum of 20 temperature readings can be recalle...

Страница 18: ...a long beep the backlight is orange then turn red Switching between mute and un mute In the power on state press and hold the sound switch button for about 2 seconds to switch the sound on or off When...

Страница 19: ...nd body temperature Body temperature contains the Forehead temperature and Ear temperature Silent the backlight is orange Switching between F C In the power off state remove the battery cover and togg...

Страница 20: ...data is being read from or written to the memory or the temperature correction is not complete A long beeps the backlight is red When the battery voltage is lower than 2 5V 0 1V the low battery symbo...

Страница 21: ...ring children place the switching device in the child mode and the symbol is displayed on the screen 6 Insert the temperature probe into the ear canal 7 Press and release the Measure button The ear te...

Страница 22: ...3 Press the Mode button the thermometer enters the Forehead mode the Head symbol is displayed on the screen 4 When measuring adults place the switching device in the adult mode When measuring children...

Страница 23: ...easure button for 1 second The temperature reading will be displayed on the screen instantly 6 If no activity is detected the thermometer will power off automatically in 10 seconds After a measurement...

Страница 24: ...the thermometer for a long time because it is sensitive to the ambient temperature 4 Make sure the sense head is free of foreign matters before use 5 Make sure the forehead has no sweat and no hairs...

Страница 25: ...Home use mild detergents Cleaning steps 1 Take the batteries out before cleaning 2 Clean the temperature probe with a soft cloth Clean the lens of the temperature probe with a cotton swab 3 Wipe the t...

Страница 26: ...ection time is completed within 1 minute and the number of repetitions per disinfection is not more than 2 times Clean and disinfect the thermometer under the temperature of 10 40 50 104 the relative...

Страница 27: ...Contact the manufacturer Er1 is displayed The ambient temperature is lower than 10 C 50 0 F or higher than 40 C 104 F Take a measurement under an ambient temperature between 10 C 50 0 F and 40 C 104 F...

Страница 28: ...lay Segment LCD Measure time About 1 second Latency Time About 3 second Measuring Range Forehead mode 35 0 C 42 2 C 95 0 F 108 0 F Ear mode 35 0 C 42 0 C 95 0 F 107 6 F Object mode 0 0 C 100 0 C 32 0...

Страница 29: ...t Degree of protection against electric shock Type BF applied part Degree of protection against ingress of water IPX0 Safety degree of using in flammable anesthetic gas blending with air oxygen or nit...

Страница 30: ...nd manufacturer s declaration Electromagnetic emission for all equipment and systems Guidance and manufacturer s declaration Electromagnetic emission The Infrared Thermometer JPD FR410 is intended for...

Страница 31: ...se in the electromagnetic environment specified below The customer or the user of the Infrared Thermometer JPD FR410 should assure that it is used in such an environment Immunity test IEC 60601 test l...

Страница 32: ...PD FR410 should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz...

Страница 33: ...E 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic is affected by absorption and reflection from structures objects an...

Страница 34: ...d the EQUIPMENT or SYSTEM for EQUIPMENT and SYSTEMS that are not LIFE SUPPORTING The Infrared Thermometer JPD FR410 is intended for use in an electromagnetic environment in which radiated RF disturban...

Страница 35: ...not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Warranty and After Sale Service The device is under warranty for on...

Страница 36: ...Shenzhen Jumper Medical Equipment Co Ltd Address D Building No 71 Xintian Road Fuyong Street Baoan Shenzhen Guangdong China Tel 86 755 26696279 Fax 86 755 26852025 Website http www jumper medical com...

Отзывы: