51
10 Setup program
10
Setup program
10.1
Setup program
The setup program enables the measuring probe to be configured using a laptop/PC. The configuration
data can be archived and printed.
The setup program can be used to overwrite changed parameters with the default settings at any time.
The connection between measuring probe and laptop/PC is established via a USB interface (Mini-B).
The setup program also enables other parameters to be configured, such as LCD display (switch-off,
automatic measured value forwarding, backlight permanently on). Each of the four measured values can
be configured (sensor selection, measurand selection, offset, measuring interval, measured value per-
manently on, etc.)
Configurable parameters
Default settings
Transmitter detection (transmitter ID)
Transmitter detection (transmitter ID), consecutive
Transmission interval
All measured values are always transmitted together with
a default transmission interval of 15 s.
Each sensor type has its own measuring interval.
•
Sensor for humidity and temperature:
5 to 3600 s (per default 90 s)
•
Sensor for CO
2
:
30 to 3600 s (per default 1200 s)
•
RTD temperature probe Pt1000:
1 to 3600 s (per default 15 s)
1st and 2nd measured value
Automatic sensor detection
3rd and 4th measured value
Without measured value