37
8 Startup and parameterization
8.6
Parameter menu details
1. In order to access the parameters menu, press the
+
keys at the same time for more than 5
seconds.
This menu allows you to adjust the following device parameters:
LANGUAGE
Choosing the display language
UNIT
Choosing the flow rate unit, the number of decimals, and the unit the count-
ers are displayed in
K-FACTOR
Entering the K-factor for the fitting (406090) used or defining it using Teach-
In calibration
OUTPUT
Parameterizing the current output AO1 (4 to 20 mA) and configuring the
transistor output DO1 and both relay outputs DO2 and DO3
INPUT
Configuring the digital input DI1
FILTER
Choosing the filter level of the measured flow rate, which affects the dis-
played flow rate and the current output AO1.
TOTAL
Resetting both counters
FRE-
QUENC.
Adjusting the mains frequency
CUT-OFF
Entering the measured flow rate value below which the device sets the
measured flow rate to 0
BACKLIT
Setting the brightness of the display and how long it stays ON, or deacti-
vating the backlight
END
SAVE N/Y
12.6 L/S
Process level
Saving the changes made within the parameters
menu or not. If the changes are saved, the device
operates with the new settings