1 Brief description
10
1 Brief
description
The device is tested according to ATEX directive 2014/34/EU and IECEx as associated apparatus with intrinsically safe output.
It meets the requirements of the following identification markings (
blue
terminals):
The input is intrinsically safe [Ex ia] so that relevant type-tested probes can be connected directly. Barriers are no longer re-
quired.
The device meets the requirements of the following identification marking (black terminals):
The measured value at the analog input can be recorded by various probes or standard signals.
It is compared with the setpoint value and switches the relay output controller K1 (LED K1 lights up) depending on the con-
troller function.
A limit value exceedance is signaled by the installed relay output limit value K2 (LED K2 lights up).
II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II (2) G [Ex eb Gb] IIC
II (2) D [Ex tb Db] IIIC
Содержание exTHERM-DR
Страница 2: ...Operating overview...
Страница 3: ......
Страница 9: ...Content...
Страница 16: ...3 Mounting 16 3 Mounting 3 1 Dimensions...
Страница 42: ...7 ATEX ignition protection type e and t 42 7 2 1 Probe arrangement in the Ex area...
Страница 63: ...9 Configuration level 63...
Страница 86: ...15 Behavior of Outputs 86 15 Behavior of Outputs...
Страница 89: ...16 Certificates 89 16 Certificates Examination certificate...
Страница 90: ...16 Certificates 90...
Страница 91: ...16 Certificates 91...
Страница 92: ...16 Certificates 92...
Страница 94: ...16 Certificates 94 IECEx...
Страница 95: ...16 Certificates 95...
Страница 96: ...16 Certificates 96...
Страница 97: ...16 Certificates 97 Ex e and t...
Страница 98: ...16 Certificates 98...
Страница 99: ...16 Certificates 99...