Product description
20
In the
<Analog module>
menu, a defined state can be selected as the trigger
for the
<Alarm output>
.
When the respective state is reached, pins 2 and 3 are connected:
• Standby
• Alarm
• Alarm + Standby
When the respective state is reached, pins 1 and 2 are connected:
• Standby/Inverse
• Alarm/Inverse
• Alarm + Standby/Inverse
Alarm output technical data
Maximum switching capacity
30 W/25 VA
Maximum switching voltage
30 VDC/25 VAC
Maximum switching current
1 A
5.5.2 REG/EPROG socket
The REG/EPROG socket has three signal outputs and one signal input.
A signal transmitter connected to the programmer input can specify the setpoint
temperature or performance as a variable. The input signal can be a voltage
source or a current source.
The signal outputs can be used at the same time. Two of the three output
channels are designed as voltage outputs, the third as a current output.
[1] Voltage output channel 1 (0-10 V)
[2] Voltage output channel 2 (0-10 V)
[3] Gnd for outputs (0 V)
[4] EPROG programmer (0-10 V/0-20 mA)
[5] Current output channel 3 (4-20 mA/0-20 mA)
[6] Gnd for EPROG programmer (0 V)
REG/EPROG socket diagram
Содержание DYNEO DD