09/21 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание CORIO CD

Страница 1: ...english Immersion Open Bath Refrigerated Circulators Operating Instructions 1 951 0800 V9 09 21 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...or operating the device 18 8 1 Securing the immersion circulator 18 8 2 Open bath tanks 22 9 Closed stainless steel bath tanks 25 9 1 Basic refrigeration baths 26 9 2 Bath fluids 27 9 3 Temperature control for external connected systems 29 9 4 Tubing 30 10 Commissioning 31 10 1 Excess temperature and low level safety devices 32 10 2 Filling 33 10 3 Pump settings 33 10 4 Switching on Start Stop 34 ...

Страница 3: ...2 15 Materials of parts in contact with the bath fluid 54 15 1 Circulator 54 16 Accessories 54 16 1 For external connection 54 16 2 For open baths 54 17 Maintenance cleaning storage 55 17 1 Maintain the refrigeration capacity 55 17 2 Cleaning 56 18 Storage 57 19 Repair service 57 19 1 Warranty 58 20 Waste disposal 59 20 1 Packaging 59 20 2 Unit 59 20 3 Refrigerant 59 21 EC conformity 60 www Global...

Страница 4: ...the development production and distribution of temperature control devices for laboratory and industry use satisfy the requirements of ISO 9001 and ISO 14001 Registration certificate No 01 100044846 Unpacking and inspection If the packaging is damaged or if you discover any concealed transport damage when you have unpacked the devices and the accessories please notify the supplier in the form of a...

Страница 5: ...r with high quality bath tanks made of transparent plastic or stainless steel Bath circulator for temperate control in an internal bath or an external application Refrigerated circulator for standard temperature control and routine tasks www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 6: ...ring tasks to be carried out in an external temperature control system JULABO circulators are not designed for the direct temperature control of foods semi luxury foods and tobacco or pharmaceutical and medical products Direct temperature control means unprotected contact between the object and the tempering medium bath fluid The devices are not suitable for use in potentially explosive environmen...

Страница 7: ...fety device which is independent of the control circuit whose value is set using a tool screwdriver A float switch acts as the low level safety device If these safety devices trip the heater and circulating pump are completely shut down Interfaces CAN bus to communicate with the refrigeration machine USB connector to act as host to update and read data USB device for remote control It is important...

Страница 8: ...esignates a danger with a medium level of risk which if it not prevented may result in death or serious injury This signal word designates a danger with a low level of risk which if it not prevented may result in minor or moderate injury Designates a possibly harmful situation If it is not prevented the system or something near it may be damaged 4 1 Explanation of other information TIP Your attent...

Страница 9: ...uch as possible Do not start the unit if it is damaged or leaking Compare the mains voltage and frequency with the specifications on the type plate Only connect the unit to a fused mains connection via a FI circuit breaker Ia 30 mA Only connect the unit to a power socket with ground contact PE protective earth The power supply plug serves as safe disconnecting device from the power supply network ...

Страница 10: ...rain the bath fluid when it is hot Check the temperature of the bath fluid before draining it for example by switching on the unit briefly Switch off the unit and pull the plug before moving the unit or carrying out service or repair work Have all service and repair work carried out by authorized specialists only Switch off the unit and disconnect it from the power supply before cleaning it Drain ...

Страница 11: ...e used by a person who is completely familiar with these substances and the unit This person must be able to assess the possible dangers in full 6 2 Operating and ambient conditions for using the unit Avoid impacts on the housing vibrations damage to the operative keypad keys and display and heavy soiling Ensure that the product is checked at regular intervals suitable for its frequency of use to ...

Страница 12: ...afety data sheets The formation of explosive mixtures is possible if the ventilation is inadequate Only use the units in well ventilated areas The unit is not suitable for use in potentially explosive environments Special substance specifications bath fluids must be observed for correct operation Caustic or corrosive bath fluids must not be used www GlobalTestSupply com Find Quality Products Onlin...

Страница 13: ... zone Note operating manual Warning about hot surface Warning of cold surface Read operating manual before switching on If external units are connected Refer to the instructions in the manuals for the external units which you connect to the JULABO unit particularly the safety instructions The connection assignment of the plugs and the technical data for the products must be observed at all times w...

Страница 14: ...s the key briefly for step by step changes Press and hold the key for fast change of setpoint 5 OK key 1 Switch the device on off 2 Store value parameter 6 Pump switchover Delivery external internal 7 Adjustable excess temperature safety device 8 Control indicator cooling 9 Control indicator heating 10 USB host interface type A www GlobalTestSupply com Find Quality Products Online at sales GlobalT...

Страница 15: ...ntrol tasks using the EasyTEMP software 15 Pump connection Return IN M16x1 external 16 Pump connection Supply OUT M16x1 external Refrigerated Circulators 17 Recessed handle front rear 18 CAN connection cable for refrigeration machine circulator 19 CAN plug for connecting to the circulator 20 Fuses Miniature circuit breakers for refrigeration machine Resettable fuses for 600F refrigeration units 11...

Страница 16: ...cock and drain port behind ventilation grille 25 Caps connectors for the cooling coil Accessories included in the supply 1x Main cable for voltage supply for the refrigeration machine 23 and circulator 11 use one only for refrigeration circulator 1x Connection cable Refrigeration machine 22 Circulator 11 1x CAN connection cable 18 for refrigeration machine circulator www GlobalTestSupply com Find ...

Страница 17: ...ta for the weight Transport the unit carefully on firm level ground The interior of the unit can also be damaged by impacts or if it is dropped Do not loiter under the unit during transportation and operation The installation site should be a sufficiently large room to ensure that it does not become too hot due to the heat emission The surface for the device should be flat and made of non flammabl...

Страница 18: ... baths Bracket for securing the circulator to JULABO refrigeration machines Pump set for connecting external applications Cooling coil for operating close to ambient temperature Stand holder with rod for securing to a laboratory stand Bath attachment clamp order No 9970420 Pay special attention to the circulator s immersion depth see Technical data when selecting the bath Place the bath on a flat ...

Страница 19: ...e on the pump Secure the bracket housing to the base of the circulator using the four screws Connect an external system Remove the union nuts and sealing plates from the pump connectors The tubing connections can be used for hoses with M16x1 connections in this state Or Secure barbed fittings to the union nuts Connect tempering hoses and secure them with tube clamps to prevent them sliding off Con...

Страница 20: ... connectors can be used for tubing with M16x1 connections in this state Or Secure barbed fittings to the union nuts Connect tubing and secure them with tube clamps to prevent them sliding off Connect the tubing for the supply and return to the pump connectors and the external consumer and secure them with tube clamps Switch the pump function to external circulation Cooling coil order No 9970100 A ...

Страница 21: ... water hoses over the connection ports and prevent slipping Bracket with cooling coil order No 9970176 Install the cooling coil on the bracket Remove the caps from the bracket Slide the ends of the cooling coil through the fastening boreholes Secure them with the washers and hex nuts Install the connection ports to the cooling coil Slide the cooling water tubing over the connection ports and preve...

Страница 22: ... tanks UL approval with CORIO CD 115 V 60 Hz Type BT5 BT9 BT19 BT27 Order numbers 9901305 9901309 9901319 9901327 Temperature range C 20 100 Approx weight kg 1 2 1 5 2 3 2 7 Dimensions WxDxH cm 23 x 38 x 38 32 x 38 x 38 38 x 58 x 38 38 x 58 x 43 Useful bath opening WxLxD cm 15 x 15 x 15 23 x 15 x 15 30 x 35 x 15 30 x 35 x 20 Filling volume Min Max l 3 5 5 0 6 0 9 0 14 0 19 0 20 0 27 0 Material Par...

Страница 23: ...5x15 Filling volume Min Max l 3 5 5 0 9 0 13 0 13 0 17 0 14 0 19 0 Material Parts in contact with the bath fluid Stainless steel Type B27 B33 B39 Order numbers 9903427 9903433 9903439 Temperature range C 20 150 Approx weight kg 8 0 17 6 14 6 Dimensions WxDxH cm 38x58x47 91x36x43 54x34x57 Useful bath opening WxLxD cm 30x35x20 66x32x15 33x30x30 Filling volume Min Max l 17 0 27 0 26 0 39 0 35 0 41 0 ...

Страница 24: ...17 9970291 Flat stainless steel bath cover B19 B27 9970292 Flat stainless steel bath cover B33 9970293 Flat stainless steel bath cover B39 9970254 Lift up stainless steel gable cover B19 B27 BT19 BT27 9970257 Lift up stainless steel gable cover B33 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 25: ...is secured to the baths UL approval with CORIO CD 115 V 60 Hz Type BC4 BC6 BC12 BC26 Order No 9905504 9905506 9905512 9905526 Temperature range C 20 300 Approx weight kg 5 2 6 4 8 2 15 0 Dimensions WxDxH cm 23x41x42 24x44x47 33x49x47 39x62x48 Useful bath opening WxLxD inner cm 13x15x15 13x15x20 22x15x20 26x35x20 Filling volume Min Max l 3 0 4 5 4 5 6 0 8 5 12 0 19 0 26 0 Materials for parts in con...

Страница 26: ...ning WxLxD inner cm 13x15x15 13x15x15 13x15x15 22x15x15 Filling volume Min Max l 3 0 4 0 3 0 4 0 3 0 4 0 5 0 7 5 Materials for parts in contact with the medium Bath and drain valve 1 4301 304H Bath Bath cover seal FKM Viton O ring on drain valve FKM Viton Type 601F 900F 1000F Order No 9461705 9461706 9461707 Temperature range C 40 150 40 150 40 150 Weight kg 36 0 52 0 49 0 Dimensions WxDxH cm 36x4...

Страница 27: ...s Hard water is not suitable for temperature control tasks due to its high lime content and will produce lime deposits in the bath Ferrous water can cause corrosion even on stainless steel Chloric water can cause pitting corrosion Distilled and deionized water is not suitable Their specific properties cause corrosion in the bath even on stainless steel Check the quality of the water you use at reg...

Страница 28: ...explosive harmful polluting In other words dangerous The user bears sole responsibility for handling these substances Use personal protective equipment The following questions should help to identify possible dangers and minimize risk Are hazardous vapors or gases produced when heated Does operation of the bath has to be conducted in a fume hood What should you do if a dangerous substance has been...

Страница 29: ...ion nuts and sealing plates from the pump connectors The tube connectors can be used for tubing with M16x1 internal connections in this state Tighten the connections with a maximum torque of 3 Nm holding the nuts a f 17 mm as you do so Second method Secure barbed fittings to the union nuts Tighten the connections with a maximum torque of 3 Nm holding the nuts a f 17 mm as you do so Connect tubing ...

Страница 30: ...g must be suitable for the pressure and temperature range which results from operation and for the bath fluid for example silicon oil must not be used with silicon tubings Secure the tubing connections to prevent them sliding off Use tube clamps Do not kink the tubing This will reduce throughput and may cause the maximum pressure in the system to be exceeded glass reactor The tube length should th...

Страница 31: ...isclaim all liability for damage caused by incorrect line voltages Commissioning the circulator with a refrigeration machine Connect the circulator and refrigeration machine using the mains lead Connect them to the voltage supply using the fitted plug on the refrigeration machine and the mains lead Connect the CAN jacks on both devices with the CAN connection cable to transfer data Cold or hot dev...

Страница 32: ...le excess temperature protector to the cut out point actual temperature using a screwdriver The actors will be shut down on all poles the circulator will show error message E 14 the Alarm control display will be lit and a continuous signal tone will sound Low level safety device IEC 61010 2 010 The float switch in this device must be moved manually in the bath to test the function for example usin...

Страница 33: ...perature falls the low level alarm will stop the tempering process Monitor the level until it reaches working temperature 10 3 Pump settings To meet all the requirements for internal and or external temperature control tasks the direction of the pump flow is continuously adjustable For this purpose the lever below the head of the circulator can be adjusted from 1 Max internal pump flow to 2 Max ex...

Страница 34: ...n Only turn off the main power switch after this indicator has stopped flashing 10 5 Setting the desired temperature value Factory setting 10 C Example Changing the desired value from 33 00 to 45 50 The temperature can be set when the device has been started or stopped The set value is saved so that it will be retained even after a power outage 1 Press the edit key or briefly to switch from displa...

Страница 35: ...alue Press the key briefly for single steps press and hold the key to adjust the values quickly 3 Save the set value as the desired value by pressing the key The new timer value will flash three times The decimal point flashes until the desired value 0 1 K is reached After the desired value is reached the timer starts and the display alternates between the actual temperature for 3 sec and the rema...

Страница 36: ...tart the unit Press the key 4th The bath will be heated to 50 0 C When the setpoint is reached allow the bath temperature to settle for approx 3 minutes 5th Start the calibration Press the Service and the key together until the comma in the display starts to flash 6th Read the bath temperature value on the calibrated thermometer and round it up or down and set it Example 48 87 C to 48 9 C 7 Press ...

Страница 37: ... that even if it is started accidentally for example after a power outage it does not pose a danger to personnel or equipment Ensure that the circulator s safety equipment is set correctly 1 Press and hold the key and 2 switch on the circulator using the main switch The switchover process is shown briefly on the temperature display LED AOn Autostart on AOFF Autostart off www GlobalTestSupply com F...

Страница 38: ...re sensors report a temperature difference of more than 20 K E 14 The cut out value of the excessive temperature protector is below the defined working temperature Set the safety temperature to a higher value E 33 The cable for the overtemperature safety sensor has been broken or short circuited E 60 Internal error Contact JULABO Service Department E 61 Connection error between Corio CD and refrig...

Страница 39: ...essive temperature protector is below the defined working temperature Set the safety temperature to a higher value E118 The internal AD converter is defective Alarms and warnings for refrigeration machines 200F 201F 300F E431 Maximum compressor current exceeded E1431 Warning No compressor current detected Alarms and warnings for refrigeration machine 600F E401 Temperature sensor evaporator outlet ...

Страница 40: ...e at the main switch 2 Eliminate the cause of the alarm 3 Eliminate the cause of the alarm or wait for approx 4 seconds depending on error type 4 Switch on the device again at the mains power switch 5 If the error occurs again a remote diagnostic is to be made Faults which are not displayed Circulating pump motor overload protection The circulating pump motor is protected from overloads After a co...

Страница 41: ...urrent value query IN_PV_01 Variable query IN_PV_03 Safety sensor query IN_PV_04 Safety potentiometer query IN_MODE_05 Start Stopp query OUT_SP_00 Setpoint input OUT_SP_01 Send setpoint OUT_MODE_05 Start Stop device 1 0 Remote operation The device can be controlled remotely via the USB interface To do this connect the unit to a PC via the interface When remote operation is active press and hold do...

Страница 42: ...e power switch is switched on and the button pressed The display shows COn Refrigeration unit always on where the required cooling capacity to maintain the bath temperature is available AUtO Automatic operation factory setting where cooling capacity is available if needed COFF refrigeration unit always off where no cooling capacity is required Reading black box data The black box is integrated int...

Страница 43: ...ithout a drain tap remove the circulator from the bath tank Small bath tanks do not have a drain tap and can be carried for drainging The temperature of the bath fluid should not exceed 50 C Enclosed baths and refrigeration machines Connect a suitable hose to the drain port 12 mm external Route the hose to a vessel or drain Open the drain valve with the knurled screw To reduce the weight the bath ...

Страница 44: ...6 15 17 Pressure at 0 liters bar 0 27 0 35 0 33 0 35 0 43 Max viscosity cSt 50 Dimensions WxDxH without bracket cm 13 2 x 16 0 x 18 4 Useful immersion depth cm 16 6 Weight kg 2 6 Ambient temperature range C 5 40 Operating temperature range C 40 150 Mains power connection V Hz 230 10 50 Power consumption 230 V A 10 For CH and GB model at 230 V A 10 Mains power connection V Hz 230 10 60 Power consum...

Страница 45: ... 44 Useful bath opening WxD cm 13 x 15 13 x 15 Bath depth cm 15 15 Filling volume from to Liters 3 0 4 0 3 0 4 0 Weight with circulator kg 26 0 25 0 Ambient temperature range C 5 40 Mains connection V Hz 230 10 50 60 Power consumption at 230 V A Nom 2 Tot 16 For CH model at 230 V A Nom 2 Tot 10 For GB model at 230 V A Nom 2 Tot 13 Mains connection V Hz 230 10 60 Power consumption at 230 V A Nom 2 ...

Страница 46: ... cm 15 Filling volume from to Liter 3 0 4 0 Weight with circulator kg 28 0 Ambient temperature range C 5 40 Mains connection V Hz 230 10 50 Power consumption at 230 V A Nom 2 Tot 16 For CH model at 230 V A Nom 2 Tot 10 For GB model at 230 V A Nom 2 Tot 13 Mains connection V Hz 208 230 10 60 Power consumpt 208 230 V A Nom 2 Tot 16 Mains connection V Hz 115 10 60 UL approval Power consumption at 115...

Страница 47: ...g WxD cm 22 x 15 Bath depth cm 15 Filling volume from to Liter 5 0 7 5 Weight with circulator kg 36 0 Ambient temperature range C 5 40 Mains connection V Hz 230 10 50 Power consumption at 230 V A Nom 4 Tot 16 For CH model at 230 V A Nom 4 Tot 10 For GB model at 230 V A Nom 4 Tot 13 Mains connection V Hz 230 10 60 Power consumpt 208 230 V A Nom 4 Tot 16 Mains connection V Hz 115 10 60 UL approval P...

Страница 48: ...cm 22 0x15 0 Bath depth cm 20 0 Filling volume from to Liter 8 0 10 0 Weight with circulator kg 36 0 Ambient temperature range C 5 40 Mains connection V Hz 230 10 50 60 Power consumption at 230 V A Nom 3 4 Tot 16 For CH model at 230 V A Nom 4 Tot 10 For GB model at 230 V A Nom 3 4 Tot 13 Mains connection V Hz 230 10 60 Power consumpt at 230 V A Nom 4 Tot 16 Mains connection V Hz 115 10 60 Power co...

Страница 49: ... 26 0 x 35 0 Bath depth cm 20 0 Filling volume from to Liter 21 0 30 0 Weight with circulator kg 52 0 Ambient temperature range C 5 40 Mains connection V Hz 230 10 50 Power consumption at 230 V A Nom 5 Tot 16 For CH model at 230 V A Nom 5 Tot 10 For GB model at 230 V A Nom 5 Tot 13 Mains connection V Hz 200 5 10 50 60 Power consumpt at 200 V A Nom 5 Tot 16 Mains connection V Hz 230 10 60 Power con...

Страница 50: ...eight with circulator kg 51 5 Ambient temperature range C 5 40 Mains connection V Hz 230 10 50 Power consumption at 230 V A Nom 6 Tot 16 For CH model at 230 V A Nom 6 Tot 10 For GB model at 230 V A Nom 6 Tot 13 Mains connection V Hz 230 10 60 Power consumption at 230 V A Nom 6 Tot 16 Mains connection V Hz 200 5 10 50 60 Power consumption at 200 V A Nom 6 Tot 16 Mains connection V Hz 115 10 60 Powe...

Страница 51: ...lass A are intended for the use in an industrial electromagnetic environment When operating in other electromagnetic environments their electromagnetic compatibility may be impacted This device is not intended for the use in living areas and cannot guarantee adequate protection of the radio reception in such environments Humidity Maximum relative humidity 80 for temperatures up to 31 C Linear decr...

Страница 52: ...ducing emissions of fluorinated greenhouse gases Among other things it regulates the emission limits use and recovery of these substances It also contains requirements for operators of systems which require contain these substances to function Under Regulation 517 2014 the operator of a system of this nature has the following duties The operator must ensure that the equipment is checked at regular...

Страница 53: ...t keep records and archive them for at least five years The records must be submitted to the relevant authority on request Refer to the text of the Regulation for further information www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 54: ...1 Springband hose clamp 1 1248 coated Tubing FPM FKM 16 Accessories 16 1 For external connection Bath fluids Tubing Shut off valve Barbed fittings Adapters 16 2 For open baths Temperature applications for samples preparation of samples for serology and clinical chemistry analysis etc Test tube racks Immersion height adjustable platforms www GlobalTestSupply com Find Quality Products Online at sale...

Страница 55: ... Empty the unit completely before moving it Transport the unit carefully 17 1 Maintain the refrigeration capacity The device is designed for continuous operation in normal conditions No regular maintenance work is required The condenser on the front should be cleaned from time to time to maintain the full refrigeration capacity 1 Switch off the device 2 Pull the plug 3 Let the unit cool down to ro...

Страница 56: ...th tanks are not resistant to solvents and pure alcohol Incorrect cleaning products will make the surface of the bath go cloudy and will dissolve the adhesive Plastic baths will therefore start to leak Clean bath tanks with wet products never rub them dry The cloths or sponges you use should not be contaminated with scouring particles or dust A good essentially smear free cleaning effect can be ac...

Страница 57: ...ct our Technical Service Department If you return a unit to JULABO Clean the unit to avoid any harm to the service personnel It is essential that you enclose a short fault description Ensure careful and adequate packing JULABO cannot accept any liability for damage caused by incorrect packaging In the interest of product improvement JULABO reserves the right to make any necessary technical modific...

Страница 58: ...The 1PLUS warranty gives the user a free extended warranty to 24 months limit to a maximum of 10 000 hours of service JULABO GmbH reserves the right to decide the validity of any warranty claim In case of faults arising either due to faulty materials or workmanship parts will be repaired or replaced free of charge or a new replacement unit will be supplied Any other compensation claims are exclude...

Страница 59: ...n this matter is available on the European Parliament s homepage The symbol for the separate collection of electrical and electronic equipment is a crossed out trash can Disposal with household waste unsorted waste or similar collections of municipal waste is not permitted Contact an authorized waste disposal contractor in your country 20 3 Refrigerant Refrigerants must be disposed of as prescribe...

Страница 60: ...21 EC conformity www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 61: ...EC conformity www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 62: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 63: ...EC conformity www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 64: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 65: ...EC conformity www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...