– 8 –
Standard Adjustment
(7) Needle-to-hook timing
1
2
Model
Dimension A
LU-1520N-7
58.7 mm
Conditions : Feed amount : 0 mm
: Needle bar rises from the lowest dead point
of its stroke.
6
Model
Dimension B
Dimension C
Dimension D
LU-1520N-7
2.3
±
0.2 mm
1.5
±
0.2 mm
0.05 to 0.1 mm
A
4
4
8
3
5
6
7
5
Standard of dimension B : Engraved marker line on the lower side of needle bar
B
C
D
0.1 to 0.2 mm
Standard : Engraved marker line on the upper
side of needle bar