– 26 –
5-4. Micro-lifter
Loosen nut
2
by turnng counterclockwse, and
turn presser sprng regulator
1
to adjust the
pressure. Turn the regulator clockwse to ncrease
the pressure and turn t counterclockwse to
decrease the pressure.
After the adjustment, tghten nut
2
.
5-3. Adjusting the pressure of the presser foot
Decrease
Increase
1
2
1
2
Loosen screw
1
, turn mcro-lfter pn
2
, and the
heght of the presser foot can be adjusted to 0 to
0.5 mm.