![JUKI DDL-9000C Series Скачать руководство пользователя страница 127](http://html.mh-extra.com/html/juki/ddl-9000c-series/ddl-9000c-series_engineers-manual_2029706127.webp)
2
)
Level 2
It can be set when a mode screen for the serviceperson level 1 or the serviceperson level 2 has been displayed.
No.
Item
Setting range
Unit
Initial value
SMS
SSH
FMS
FSH
SMS CE SSH CS FMS CE FSH CE
K023
Presser device
0: Equipped/1: Non-equipped
0 to 1
-
0
0
0
0
0
0
0
0
K024
Reverse feed stitching speed (at end)
When the set value is 150, the set value of a memory
switch U008 becomes effective. Other than that, the val-
ue lower than that of the memory switch U008 becomes
effective.
150 to 3000
sti/min
150
150
150
150
150
150
150
150
K026
Operational settings of BTSW
0: Normal/1:Stopping double touch Hsw/2: Stopping
Hsw/3: Stopping Usw
0 to 3
-
0
0
0
0
0
0
0
0
K034
Number of needles for prohibited reverse feed
stitching (at end)
0: Prohibited and disabled
0 to 19
Stitch
2
2
2
2
2
2
2
2
K046
Function for lifting of a presser foot at the time of
power activation
0: OFF/1: ON
0 to 1
-
0
0
0
0
0
0
0
0
K050
Waiting time after lowering of a presser foot
Waiting time until a principal axis begins to start after
lowering of a presser foot
10 to 100
ms
40
40
40
40
40
40
40
40
K067
Speed correction for presser strength
Correct the presser strength with the sewing speed.
0: Without speed correction/1: With speed correction
0 to 1
-
0
0
0
0
0
0
0
0
K072
Function for selection of the rise of a sewing ma-
chine
0: Normal/1-400: Restriction on a rise
0 to 400
-
0
0
0
0
260
260
260
260
K086
Waiting time until the reverse-rotate needle-up starts
0 to 250
ms
100
100
100
100
100
100
100
100