24
JUDO PROFIMAT-PLUS
Fault
6.
Fault
The opening of the units and the replace-
ment of the water pressure charged parts
may only be effected by authorized
personal in order the ensure the unit
security and its tightness.
The occurrence of a failure is indicated by
the red control lamp.
Deletion of the error message:
Pull of the power supply out of
the socket. Replug it again after
approximately 5 seconds!
Fault help:
Fault
Cause
Removal
Continous signal tone.
The DIP-switch was
wrongly adjusted.
Set DIP-switches to the correct
position! (see chapter “Setting the
backwashing interval” and “Po-
tential-free input”)
Red indicator lamp
“Fault” blinks, signaller
beeps.
Electrical or mechanical
defect.
–
Delete the error message!
–
Start backwashing again by
hand release!
If the fault occurs again:
–
Pull of the power supply out of
the socket
–
Inform the plumber or nearest
customer service centre!
–
If water escapes close ball
valves!
All three LEDs blink.
Services to be needed.
See chapter “Warranty and ser-
vices”
Backwash water
continues running.
Flush valve not fully
closed.
–
Start backwashing again by
hand release!
Dirt in the flush valve.
Decrease in water flow
rate.
Sieve is clogged.
Leaks in the filter hood.
–
Pull of the power supply out of
the socket!
–
Close ball valves!
–
Inform the plumber or nearest
customer service centre!
–
If water escapes close ball
valves!
Filter hood becomes
turbid.
Filter hood was exposed
to higher temperatures or
solvents.
Hairline cracks in the
filter hood.