background image

JUDO HEIFI-TOP

5

Intended use

2.

Intended use

The installation and operation of the filter is
subject to the following existing national
regulations.

In addition to the operating instructions and
the obliging regulations concerning accident
prevention that exist in the country of opera-
tion and the location of use, the established
technical regulations concerning safe and
professional work, should also be observed.

The filter has been developed and manufac-
tured using state of the art technology and the
established safety regulations in Germany.

The filter may only be operated in accor-
dance with the manufacturer’s specifica-
tions. Any other operation or operation be-
yond the specified use, is not in accordance
with the manufacturer’s specifications.

Additional dangers may result in the event of
the device not being operated in accordance
with the manufacturer’s specifications and
non-observance of the danger symbols or
safety instructions. The manufacturer / sup-
plier cannot be hold liable for any damages
caused by these additional dangers. The
operator is responsible for these risks.

The use of the device in accordance with the
customer’s specifications includes the
observance of the operating instructions.

The manufacturer / supplier should be con-
sulted prior to any operation of the filter
other than in the operational areas stated in
these operating instructions.

The filter may only be operated in a techni-
cally faultless condition, in accordance with
the manufacturer’s specifications and the
stated safety and danger relevant instruc-
tions and under observance of the operating
instructions!

Any functional defects are to be removed
immediately!

2.1

Water pressure

The water pressure must not fall below
15 psi (100 kPa) as otherwise the back-
washing can be impaired! If the filter is not
backwashed regularly a pressure loss can
result and this can impair the filter function.

2.2

Notes on special dangers

2.2.1 Electrical equipment / 

installations

Electrical devices/equipment that are not
splash-water proof and are situated in the
direct vicinity of the filter may be damaged
by water leaking from the filter caused as a
result of the device not being operated in
accordance with the manufacturer’s specifi-
cations. In addition this may also result in
short circuits if these electrical devices/
equipment being connected to the electrical
power supply. In the event of such cases
persons are at risk and may sustain elec-
trical shocks. Therefore any electrical
devices/equipment situated in the direct
vicinity should be splash-water proof,
respectively comply with the statutory
requirements for wet areas (IP44).

There must not be any electrical
cables and devices underneath or in
the immediate vicinity of the filter!

Содержание JHF-T

Страница 1: ...safety information before installing and putting the unit into service These instructions must always be issued to the owner user Installation and operating instructions JUDO HEIFI TOP 2 Backwash fil...

Страница 2: ...Customer we would like to thank you for your con fidence in us which you have shown by purchasing this device The product you have purchased is a filter developed us ing state of the art technology Th...

Страница 3: ...e place where the filter is installed This instruction manual is intended to make it easier to familiarize yourself with the filter and its possible intended uses The instruction manual contains impor...

Страница 4: ...to observe the general danger symbols can result for example in the following risks Failure of important functions of the filter Danger to persons due to electrical and mechanical effects Danger to p...

Страница 5: ...prior to any operation of the filter other than in the operational areas stated in these operating instructions The filter may only be operated in a techni cally faultless condition in accordance with...

Страница 6: ...d per sonnel The chapter Intended use must always be observed The pipes must be able to safely support the filter Otherwise mechanical damage or fractures bursts can occur in the pipes This can result...

Страница 7: ...uilt in rotary flange is used as a connecting element between the pipe and the filter The built in rotary flange is suitable both for horizontal and vertical pipes It is suitable for both horizontal a...

Страница 8: ...as far as it will go see fig 2 II Tighten the four flange screws ATTENTION see chapter Safety information and dangers due to non compliance The section of the profiled flange gasket must point toward...

Страница 9: ...ening the ball valve the filter is backwashed see chapter Backwashing Caution risk of scalding After approx 2 to 3 liters of backwashing wa ter has been flushed through the ball valve must be tightly...

Страница 10: ...ugh of the device is brought about Step 1 min 10 liter Step 2 Fig 6 The backwash performance will be started through the turning on of the flush faucet Hold available a collecting vessel with a capaci...

Страница 11: ...utlet of the rapid venter is in a one turn open position to ensure an unhindered escape of the air After backwashing and venting the filter is ready for use Functional description 5 2 Functional descr...

Страница 12: ...illing water must be refed 5 4 Backwashing interval If the filter is installed retrospectively in old heating systems the backwashing should be carried out every 14 days until the back washing water c...

Страница 13: ...s not yet been turned back Ball valve handle at the front Turn the handwheel back to the right up to the limit stop The filter is now back in the operating position The heating system s circulating pu...

Страница 14: ...se cleaners and glass cleaners can contain up to 25 solvents or alcohol spirits These substances can chemically attack the plastic parts which can lead to brittleness right up to brittle fractures The...

Страница 15: ...F T 1 8060056 JHF T 2 8060057 Nominal pressure Model Operating pressure Nominal pressure JHF T 2 22 150 psi 150 1000 kPa PN 10 Weight Model Weight JHF T 4 9 kg JHF T 1 5 0 kg JHF T 1 5 5 kg JHF T 1 13...

Страница 16: ...E Depth to pipe centre F Connection dimension residual water G Nominal diameter Model A B C D E F G JHF T 180 7 0 130 5 0 245 10 138 5 4 170 6 7 105 4 1 15 0 6 JHF T 1 195 7 5 130 5 0 245 10 138 5 4...

Страница 17: ...JQE 1 or 2 with bayonet fixture and screw connection 9 7 Accessories JHF T 2 JHF F feed station Order no 8060040 The JUDO HEIFI F L feed station consists of a ball valve pressure reducer and manometer...

Страница 18: ...18 JUDO HEIFI TOP Spare parts 10 Spare parts 9 10 11 13 12 8 7 6 5 4 3 2 2 14 15 1...

Страница 19: ...3 Housing JUDO HEIFI TOP 1 2060073 4 Circular brush diameter 60 1 1980214 5 Clamping nut 1 2060061 6 Dowel pin 4m6x10 1 1650226 7 Pressure spring 1 1650224 8 Lock housing 1 2060062 9 Shut off valve 1...

Страница 20: ...ved for modifications as a result of technical progress or further developments Claims with regard to models or products are excluded 1701610 2017 01 JUDO Water Treatment Inc 240 Lesmill Road Toronto...