Intended use

The device is for the

Filtration

Pressure reduction

Backflow prevention

of drinking water in domestic water pip-

ing and for residential, commercial and

industrial use. It removes coarse and fine-

grained particles from the drinking water,

which are larger or equal to the mesh size

of the filter, in order to prevent

pipe damage caused by corrosion

malfunctions of fittings or control and

regulating devices caused by foreign

bodies.

The device can be installed in all commer-

cially available drinking water pipes. Both

installation and use of the device are sub-

ject to the applicable national regulations.

INFO_NO_HEADER

Particles that are smaller than the

mesh size of the filter supplied and

materials causing cloudiness cannot

be filtered out of the water.

1.2

Application limits

1.2.1 Water quality

The water to be filtered must comply with

the European Drinking Water Directive

(98/83/EC). Before using the device with

water that does not comply with this Direc-

tive, it is essential to consult the manufac-

turer.

1.2.2 Water pressure

CAUTION

The water pressure must not exceed

16 bar input pressure. The device

must not be installed if the mains

pressure is above 16 bar (even for a

short time)!

Nominal pressure

PN 16

Operating pressure 1.5 bar - 16 bar
Downstream pres-

sure

1.5 bar - 6 bar

Factory setting:

4 bar

The water pressure must not fall below

1.5 bar as otherwise backwashing can be

impaired!

INFO_NO_HEADER

Starting at an operating pressure

of 10 bar, increased wear can be

expected!

1.2.3 Water and ambient tempera-

ture

The filter is suitable for use in cold drinking

water up to a maximum water and ambient

temperature of 30 °C.

1.3

Safety instructions

1.3.1 Electrical danger

ELECTRO_NO_HEADER

Risk of electric shock

No electrical wiring or equipment that is

not splash-proof may run or be stored

below the device. Electrical devices/

equipment located in the vicinity of the

device must be splash-proof or comply

with the legal regulations for wet rooms.

4

JUDO JPM+  

1702272 • 2020/07

Содержание 8170200

Страница 1: ...Installation and operating instructions JUDO PROMI PLUS Domestic water station 1 Valid for EU countries and Switzerland Language English Read before use and store...

Страница 2: ...rinting even in excerpt form is only permitted with special approval Dear customers Thank you for the confidence you have shown in us by purchasing this prod uct You have purchased a state of the art...

Страница 3: ...tallation of the device 9 3 4 Draining of the backwash water 10 3 5 Commissioning 11 4 Operation 11 4 1 Setting the downstream pres sure 11 4 2 Cleaning of the sieve insert backwashing 11 4 3 Conversi...

Страница 4: ...omply with the European Drinking Water Directive 98 83 EC Before using the device with water that does not comply with this Direc tive it is essential to consult the manufac turer 1 2 2 Water pressure...

Страница 5: ...rotary flange fitting must be fitted so that it is free from mechanical stress or strain Otherwise mechanical damage to the pipe or the rotary flange fitting up to and including breaks can result For...

Страница 6: ...to the device e g Direction of flow arrow Type label Cleaning information must be observed and maintained in legible condition 1 5 Units used Unit Conversion bar 1 bar 105 Pa 0 1 N mm2 DN 20 1 DN 25...

Страница 7: ...f the pressure reducer 10 Inlet pressure gauge 11 Outlet pressure gauge 12 Outlet backwash water 2 3 Materials used The materials used are resistant to the physical chemical and corrosive loads expect...

Страница 8: ...test according to DIN EN 13443 1 and DIN 19628 and are therefore not permitted to wear the approval mark 3 Installation CAUTION The device may only be installed by qualified technical personnel Insta...

Страница 9: ...ce CAUTION If no bypass valve is installed a shut off valve must be installed upstream and downstream of the unit in order to interrupt the water supply during installation mainte nance repair or malf...

Страница 10: ...of the wastewater can be drained simulta neously If a wastewater connection directly beneath the device is not possible the backwash water can be drained away via a hose or a pipe that is connected fr...

Страница 11: ...ia the pressure reducer The factory pre set downstream pressure of 4 bar can be changed to a value between 1 5 bar and 6 bar depending on the upstream pressure 1 Undo the countersunk screw on the hand...

Страница 12: ...a more frequent backwashing is necessary 4 2 2 Due date of backwashing Every two months a beep reminds you that the backwashing is due To switch off the beep press the reset but ton on the handwheel c...

Страница 13: ...ts WARNING The device may only be repaired by qualified technical personnel Only use original spare parts for repairs Before performing work on the device that goes beyond pure operational use the dev...

Страница 14: ...the flange surfaces against damage to ensure proper sealing Protect the device from dirt so as not to impair drinking water hygiene Store the device in a frost free place to prevent damage caused by...

Страница 15: ...line cracks on the filter bowl Filter bowl was exposed to high temperatures or solvents Inform the installer or the closest customer ser vice point If water escapes close shut off valves Have the filt...

Страница 16: ...ecked annually on the outlet pressure gauge both at zero flow and at peak flow large withdrawal If necessary the setting of the outlet pressure must be readjusted To ensure the process operates succes...

Страница 17: ...bar 1 5 bar 6 bar Factory setting of downstream pressure 4 bar 4 bar 4 bar Mesh size sieve insert2 100 m 0 1 mm 100 m 0 1 mm 100 m 0 1 mm Water temperature and ambient temperature max 30 C max 30 C m...

Страница 18: ...th of the device C Height above the pipe middle D Height below the pipe middle E Installation depth up to the pipe middle F Waste water connection up to the pipe middle G Waste water nominal diameter...

Страница 19: ...Technical data 7 3 Spare parts 1702272 2020 07 JUDO JPM 19...

Страница 20: ...r alarm consisting of pos 1 2 3 1 2010495 49 1 Handwheel lid 1 2 Backwash reminder alarm 1 3 Battery 1 5 V Typ AAA set with 2 pcs 1 2060347 8 4 Countersunk screw M5 12 1 5 Disc A 6 4 1 6 Memo handwhee...

Страница 21: ...sieve 1 33 O ring 25 3 5 1 34 O ring 52 3 5 1 35 Cylinder screw M6 25 Set with 4 pcs 1 2060333 2 36 Pressure gauge seal 2 37 O ring 14 5 2 5 4 38 Pressure gauge connection piece 2 39 Pressure gauge 0...

Страница 22: ...recycling system To protect environment old appliances and used batteries must not be disposed of with household waste Instead use the local col lection and return points which are commit ted to free...

Страница 23: ...Maintenance log 9 Maintenance log Product designation Domestic water station Order number Serial number Date Work activities performed Company signa ture 1702272 2020 07 JUDO JPM 23...

Страница 24: ...judo online ch judo online ch BENELUX JUDO Wasseraufbereitung GmbH Filiaal Filiale Benelux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Phone 32 0 24 60 12 88 Fax 32 0 24 61 18 85 E mai...

Отзывы: