OPERATING AND INSTALLATION
– MARCH 2013
WWW.JSI-UK.COM
Page 8 of 9
Operating controls
– 5 Speed Digital
o
Start fan by pressing button
A
on control panel
o
Increase or decrease speed by pressing buttons
B
or
D
(maximum 5 speed)
o
When the timer button
F
is pressed for 2 seconds, timer function will be on for 15
minutes.
o
When the aluminium filter is “dirty”, the warning is given by displaying the letter “C” on
the display panel usually every 2-3 weeks. When the filters are cleaned, dried and re-
fitted, button
A
should be pressed for 3 seconds to clear the
C
letter on the display
panel. The letter
“E”
will appear on the display and the product will start working again
as normal. It is important to wash the filters when the device alerts you to protect the
electronics and ensure optimum extraction.
Operating this appliance with the filter warnings on may invalidate the warranty.
o
If you want to continue using your hood without deleting the letter
C
on the display, the
active speed number will appear for 1 second when you first start the hood and then
the
C
will appear with the hood running as normal.
o
Please note that the letter
C
will appear after 60 hours
o
Warning
– do not attempt to clean the carbon filters. These must always be replaced.
o
Remote control can be used instead of touch control (only on RC models).
A = Motor on or off
B = Increase Speed
C = Decrease Speed
E = Lights on or off
Troubleshooting Chart
Check
electrical
connections.
Voltage
should be
220v and
must be
earthed
Check motor
switch.
Motor switch
must be in
“on” position
Check
batteries in
remote if
applicable
Check
lamp
switch.
Lamp
switch
should
be in
“on”
position
Check outlet
chimney (air
outlet must
be open
Check
the
bulbs
are
working
Check
Aluminium
filter
–
Aluminium
filter cassette
should be
washed
monthly.
Change
carbon filter
Extractor is
not working
Extractor lamp is not
illuminated
Extractor gives
poor suction
Change
fuse for
1 amp.
A B C D E F
Letter ‘C’
displayed (Filter
Warn)
Check
the
fuse on
control
board
Extractor not
venting to
outside