background image

 

 

 

 

 

 

 

 

 

 
 
 
 
 

NOTICE D’UTILISATION 

USER MANUAL 

 

Spy RF U 

 

 

          

 

 

06251F 

Содержание Spy RF U

Страница 1: ...NOTICE D UTILISATION USER MANUAL Spy RF U 06251F...

Страница 2: ...accordement des sondes 6 IV UTILISATION 6 a Arr t 6 b Activation 7 c Attente 7 d Programmation 7 e D marrage des mesures 7 f Mode automatique 7 g Mode manuel 8 h Indication d alarme 8 i Arr t des mesu...

Страница 3: ...6VDC 10 A MARQUAGE CE cet appareil est certifi conforme la r glementation europ enne pour la s curit lectrique la inflammabilit l mission de rayonnements perturbants et l immunit aux perturbations le...

Страница 4: ...du plafond pour viter les obstacles et les passages de personnes Dans la mesure du possible placer le Spy RF ModeM dans une position centrale par rapport aux points de mesure Essayer de les placer de...

Страница 5: ...de diff rentes natures Les capteurs peuvent le cas ch ant tre d connect s de l enregistreur pour leur remplacement ou pour l change de l enregistreur lui m me Mod le 1Voie Mod le 2Voies Support mural...

Страница 6: ...odem se reporter la notice de Sirius pour connaitre les configurations minimales requises a Arr t A r ception le SPY RF est l arr t Seule l horloge est active Il ne peut ni mettre ni recevoir Embase m...

Страница 7: ...guration du SPY RF est r alis e l aide du Logiciel Sirius voir notice Sirius puis transmise au SPY RF par l interm diare du Spy RF Modem e D marrage des mesures Le SPY RF est muni de 2 modes de d marr...

Страница 8: ...alarme Le SPY RF est muni de plusieurs indicateurs simultan s de d passement de seuil Pr alarme Alarme T moin d alarme rouge Clignote toutes les 15 Indicateur de seuil haut ou bas Valeur mesur e clig...

Страница 9: ...t AUTO CONTROLE Mode stockage Cette fonction permet de personnaliser une action de v rification des mesures Un appui court sur le BP L action est m moris e et appara tra sur la courbe lors de l exploi...

Страница 10: ...arr t des mesures V REMPLACEMENT DE LA PILE Quand la pile du SPY RF doit tre remplac e l afficheur vous le signal par le message suivant Pour remplacer la pile suivre les tapes suivantes VI RESET En c...

Страница 11: ...50 C et 0 5 C en dehors Intervalle de mesure 1s 90 min Taille m moire 20 000 mesures Conditions assign e de fonctionnement 30 70 C Temp rature de stockage 40 85 C Port e radio en champ libre 1 km Ban...

Страница 12: ...JRI Maxant 12 IX FICHE D APTITUDE L EMPLOI...

Страница 13: ...met d assurer le fonctionnement performant de vos appareils ou de votre installation Vous n aurez plus vous soucier de l entretien de vos appareils Ce contrat de maintenance vous permet de b n ficier...

Страница 14: ...ring 18 f Connecting probes 18 IV INSTALLATION ERREUR SIGNET NON DEFINI V USE 18 a Stop 18 b Start 19 c Waiting mode 19 d Configuration 19 e Measurement start 19 f Automatic start 19 g Manual start 20...

Страница 15: ...6VDC 10 A CE MARKING this equipment is certified to comply with the European regulation for the electric security inflammability disturbing radiation emission and immunity to surrounding electric dist...

Страница 16: ...to 40cm from the ceiling to avoid obstacles and moving persons If possible place the Spy RF in central position regarding the Spy RF recorders Try to place them preferably at sight of each other On t...

Страница 17: ...ion of different type of probes very easy The probes can otherwise be disconnected from the recorder to be changed or to change the recorder itself 1 channel 2 channels Wall mounting bracket Connector...

Страница 18: ...the minimum system requirements a Stop When you receive it your SPY RF is stopped Only the time clock is active It can neither emit nor receive anything Male connector on SPY RF U Female connector on...

Страница 19: ...ration is done from the Sirius software see Sirius user manual and then transferred into your SPY RF by radio frequency thanks to a Spy RF ModeM e Measurement start The SPY RF has 2 starting mode auto...

Страница 20: ...mber measurement unit and memory status The green LED flashes every minute h Alarm visualisation The SPY RF is equipped with different alarm indicators when a threshold limit is overpassed Pre alarm A...

Страница 21: ...mode and AUTO CONTROL Storage mode This function enables you to customise an action of measurement check up You just have to press shortly on the pushbutton The action is recorded and will appear on...

Страница 22: ...r To remove stubborn dirt use a soft cloth impregnated with a mild detergent non abrasive Then wipe gently with a soft dry cloth Never use benzene thinners alcohol or solvents of any kind which may ca...

Страница 23: ...e EMT 0 20 C from 20 to 50 C and 0 5 C outside Recording interval 1s to 90 min Memory size 20 000 measurements Operating conditions 30 70 C Temperature for storage 40 85 C Radio range in free field 1...

Страница 24: ...JRI Maxant 24 XXI CAPACITY OF OPERATION DATA SHEET...

Страница 25: ...w up performed by specialists That s why JRI Maxant has created maintenance contracts We bring you a global solution which makes your maintenance easier This overall service offer includes maintenance...

Отзывы: