4-40
When the "SEND" or "RECEIVE" of data IN/OUT1 or data IN/OUT2 is set and one port is set,
the other port is also set concurrently. The message that is shown below is displayed to
prevent the unintentional setting of the other port. When setting a port, select “YES”. If “NO”
is selected, the port is not set.
2) Selecting
IEC
For IEC, there is no need to select VERSION.
4. Select “SEND” from “DATA IN/OUT” by using
.
5. Select an output sentence by using
and set an output cycle.
The cycle can be selected within the range from 1 second to 9 seconds and when OFF is selected,
the sentence is not output.
6. Return control to the BIT RATE selection screen and select BIT RATE by using
.
Available bit rates are “4800”, “9600”, “19200”, and “38400”.
Supplement