23 | Installation
1.1.2 DP Operator Panel
1.1.2.1 Joystick and Tracker ball
The DP Operator panel consists of:
A) Joystick panel with integrated rotation button and mode select buttons.
•
Panel size (HxWxD): 144 x 144 x 135.
•
Joystick 2-dimensional coordinate type with 75mm stick.
•
Heading knob by turning joystick lever.
•
Integrated push buttons.
B) Tracker Ball for controlling large TFT screen.
•
Panel size (HxWxD): 144 x 144 x 20.
•
Trackerball.
•
Numeric keyboard.
Figure 8: Joystick
Figure 9: Tracker Ball
The DP system operation modes are selected with – and indicated on - the push buttons on the joystick panel or at the
screens shown at the TFT monitor of the DP workstation. Operation mode change is only possible when the Joystick and
RATE OF TURN knob (also called HEADING knob) are in neutral position.
In each Operation Mode the appropriate settings can be displayed and adjusted by pressing the SETTINGS push button.
Note Settings can be entered via the tracker ball and the buttons on the large screen.