NXU-2B Operations Manual
3-3
Interoperability Now!
3.3.2
IP Address and Subnet Mask
Use these entry fields to set the desired IP Address and Subnet Mask to configure the NXU-2B
for the network where it is going to be deployed.
Note: Be sure to write down the new IP Address so that you can remember where to
access the unit on your network. Once you press Save Changes the unit will
reconfigure itself.
If you have a DHCP server on your network, you may configure the NXU-2B to obtain its IP
address, subnet mask, and gateway address via DHCP. Setting the NXU-2B IP address to 0.0.0.0
will cause it to attempt to contact a DHCP server on power-up.
Note: If DHCP is to be used, it should only be used on client NXU-2B units. The use of
DHCP is not recommended for NXU-2B Server units since the IP address assigned by
the DHCP server is not generally known and is subject to change.
3.3.3
Gateway IP Address
If you are using a gateway, set the gateway address (the address of your router). If on a LAN
with no gateway, leave the gateway address set at the default address 0.0.0.0.
3.3.4
Unit is a (Client or Server)
Sets this NXU-2B to function either as a Client or as a Server. A Client is able to make or break
connections with Servers; Servers can only accept connection requests from a Client.
3.3.5
Remote IP and Remote Port (applicable only to Client units)
If the NXU-2B is set as a Client, you must provide the IP address and Port of the server that it
will attempt to connect to.
If you do not want the client unit to connect to a server automatically at power-up, set the Remote
IP (server IP) address to 0.0.0.0
3.3.6
VoIP Port
The VoIP Port is the port used by the NXU-2B for receiving audio from the network, and defaults
to 1221. Under normal circumstances, this should not be changed. The port number must range
from 1 to 65535 and be different from the command port.
Note: The server port on a client unit corresponds to the VoIP port on the server unit that the
client unit is going to connect to. Also, the client unit’s VoIP port does not need to match the
server unit’s VoIP port (or client unit’s server port) for the two units to communicate. The server
unit will automatically determine where to send audio so the client unit receives it.
Содержание NXU-2B
Страница 8: ...NXU 2B Operations Manual viii blank page...
Страница 18: ...NXU 2B Operations Manual 1 10 End of Section One...
Страница 28: ...NXU 2B Operations Manual 2 10 End of Section Two...
Страница 60: ...NXU 2B Operations Manual 6 8 End of Section Six...
Страница 62: ...NXU 2B Operations Manual 7 2 End of Section Seven...
Страница 68: ...NXU 2B Operations Manual 8 6 End of Section Eight...