www.jps.com.tw
80
13.6.3 Rotary Switch Group Digital-Output
Example for using Rotary Switch:
1.
Set the speed limit Pr.128 = 2000.
2.
Pr.065 = 73
Æ
Set FWD.
3.
Pr.066 = 74
Æ
Set REV.
4.
Pr.278 = 19
Æ
Select speed command set from Rotary Switch.
5.
Pr.118 = 0
Æ
Select Rotary Switch type: Start from 0, with max. limit.
6.
Set DI1(203), DI2(204), DI3(205)
Æ
Set the input definition for Rotary Switch.
7.
Pr.152 = 1000
Æ
Set max. limit value of Rotary Switch.
8.
Connect the signals A, B, Store of Rotary Switch to the DIs those were defined by step 6.
9.
It is necessary to reset the drive to let the changes available.
10.
Start to run forward and the drive will run in the speed that set by Rotary Switch. If the Rotary Switch
is see in 500, the speed will be Pr.137 / Pr.152 * Pr.128 = 1000rpm.
11.
Press the Store bottom, the value in Pr.137 will be stored into Pr.152.