15
ENGLISH
10�7 “KEYBOARD LOCK” FUNCTION
This function makes it possible to lock the keyboard in
order to prevent unintended changes.
To activate/deactivate this function:
a) Using keys , select the Configuration menu and
press .
b) Select the
“7”
item using button and confirm by pressing
button .
c) Select submenu
[10]
confirm by pressing button .
d) Set one of the following parameters using buttons :
„
Off
” Keyboard lock off
„
Lo
”
Only the ignition/extinguishing button is
active
„
Hi
”
Keyboard lock on
e) Press button , to confirm the setting.
10�8 MINIMUM TEMPERATURE
(Only in configuration 1)
It is possible to program the minimum temperature
below which the stove will ignite (besides programmed
time intervals). To change the “minimum” temperature
parameter:
a) Using keys , select the Configuration menu and
press .
b) Select the
“7”
item using button and confirm by pressing
button .
c) Select submenu
[9]
confirm by pressing button .
d) The parameter will start to flash, change it using buttons
(OFF; 3-20
°
C)
.
e) Press button , to confirm the setting.
10�3 “REIGNITION DELTA” FUNCTION
The reignition delta is the number of degrees below the
extinguishing temperature, which, when exceeded, will
cause the stove to reignite automatically. For example,
if the stove is programmed to extinguished at 20°C (Eco
mode on), and “Reignition delta” is set to 4°C, the stove
will reignite after detecting a temperature of 16°C or
lower.
To change the desired Reignition delta value:
a) Using keys , select the Configuration menu and
press .
b) Select the
“7”
item using button and confirm by pressing
button .
c) Select submenu
[8]
confirm by pressing button .
d) The parameter will start to flash, change it using buttons
and (from 0.5°C to 5.0°C).
e) Press button , to confirm.
10�4 “AUTONOMY” FUNCTION
This function displays the hours of autonomous work
remaining until it will be necessary to replenish pellet.
Using the arrow keys, select icon
, and the estimated
number of hours of autonomous work until it will be
necessary to replenish pellet will be displayed on the
screen. The hours of autonomous operation remaining
are calculated based on the parameters currently set on
the stove.
Estimated values are sufficiently reliable under the
condition that, upon every full replenishment of pellet,
the “FULL” value will be selected and confirmed. The
“Lo” value signifies reserve status.
10�5 “REPLENISHMENT” FUNCTION
This function makes it possible to register filling of the
container with pellet.
In this way, based on operating parameters, the stove is
capable of calculating the hours of autonomous operation
remaining until it will be necessary to replenish the
container.
After complete filling of the pellet container:
a) Using the arrow keys , select the fuel icon
, then
press the send button .
b) Using keys , select the
“FULL”
option and press the
“send” button .
To disable this function, select
“OFF”
instead of
“FULL”
.
10�6 REIGNITION AFTER POWER FAILURE
After a break in power supply, the stove will automatically
reignite and perform auto-diagnostics after power is
restored.