Battery safety information
Type:
Primary lithium metal
Lithium metal content:
Below 1gram lithium pr battery cell
Approximate weight:
116grams
Chemical system:
Lithium iron disulfide
Designated for recharge:
No
For information regarding the physical and chemical properties, the
potential health and safety measures and the environmental effects of the
battery used with this product, refer to the manufacturer’s safety
information documentation.
The safety information is available for download at
http://jotron.com/product/tron-60s-epirb-manual-bracket/.
12.1
Handling and storage
This product should be stored in a cool and well-ventilated area. Elevated
temperatures can result in a reduction of battery life. Locations that handle
large quantities of lithium batteries must ensure the batteries are isolated
from combustibles. A short circuit for a few seconds will not seriously affect
the battery. A prolonged short circuit will cause the battery to lose energy,
generate significant heat and can cause the safety release vent to open.
The contents of an open battery, including a vented battery, when exposed
to water, may result in a fire and/or explosion. Crushed or damaged
batteries may result in a fire. A battery that is disassembled or exposed to
water, fire or high temperatures can explode or leak causing burns.
12.1.1
Transportation
The product described in this manual is subject to follow special packing
instructions and/or transportation regulations. Information regarding these
regulations (in accordance with ICAO/IATA, IMDG code and/or ADR/RID) is
included in the product safety information (PSI) and/or in the test summary
report (TSR) (in accordance with UN test 38.3.5) and available for download