Doc. No.: 85525 Rev. M
jotron.com
Page 35 of 48
3
Low battery voltage
4
Low power on 121.5 MHz transmitter
5
PLL on 406 MHz transmitter out of lock
6
PLL on 121.5 MHz transmitter out of lock
7
EPIRB module not programmed or programming not
complete
Table 4 Tron 60S/GPS self-test error codes (flashes)
9.2.2
Extended self-test (GPS test) (only Tron 60GPS)
Upon completion of an extended self-test, a self-test will automatically
occur. However, only when the extended test is successful. During an
extended self-test, a GPS position is received. During the automatic self-
test, the position is sent on 406.037 MHz. An EPIRB tester can be used to
verify the GPS position during a self-test.
Limit this test to a maximum of once a month as this
testing reduces the lifetime of the EPIRB battery. The
Tron 60GPS can only complete 60 GPS tests during the
lifetime of 1 battery.
To perform an extended self-test including GPS, do the following:
1.
Remove the EPIRB from the bracket.
2.
Move switch to the test position twice within 3 seconds and
release back to the ready position.
The EPIRB will beep shortly every 3 second until the GPS
position is acquired.
Keep hands and/or other objects away from the
antenna.