Jotron AS| TR7750C: Operators Manual
Installation
Page 4-5
P/N: 84748 (G)
Menu path:
Interface config ►
Parameter
Range
Default
Details
RS485
(TX and RX)
Bitrate
1200
– 115200
1200
Set the bit rate to use on the RS485 port
RS485
(TX and RX)
Address
1
– 255
1
Set the address to use on the RS485. In a
remote system using the RS485
communication port, all units that are
interconnected need to have a unique
address in order to avoid collisions and
misinterpretation of data.
RS485
(TX and RX)
Protocol
Legacy |
standard
Legacy
The protocols are described in the data
manual.
Legacy
uses a protocol where the 9. bit is
used for address recognition, this is the
protocol used on the previous radio models
(TA7450, RA7202) and is compatible with
the RACS II PC software and the RCU
remote control unit.
Standard
is an eight bit protocol that uses
the multidrop capability of the RS485 bus.
For more information on protocols, refer to
the SW manual.
Menu path:
RX config ►
Parameter
Range
Default
Details
Audio
( RX)
Mute on transmit
False | True
True
Set this to true if the receiver should be
muted while transmitting. Requires that the
Tx busy signal on the transmitters RX
connector is routed to the TX busy input on
the receiver REM connector. (p.4)
Table 4.6-2, Settings associated with the transmitter - receiver interconnection
Содержание RA-7203C
Страница 1: ......
Страница 7: ......
Страница 32: ...Jotron AS TR7750C Operators Manual Installation Page 4 4 P N 84748 G...
Страница 44: ...Jotron AS TR7750C Operators Manual Installation Page 4 16 P N 84748 G...
Страница 63: ...Jotron AS TR7750C Operators Manual Operating Instructions Page 5 13 P N 84748 G...
Страница 88: ......