background image

JD 27/JD 227  

Installation and Maintenance Manual

 A

+

Содержание JD 227

Страница 1: ...JD 27 JD 227 Installation and Maintenance Manual A...

Страница 2: ...n 7 Installation clearances 8 9 About JD 27 JD 227 10 Here is how your range works 10 Installation and mounting 11 Connecting outdoor air to the wood burning range 12 Replaceable parts 12 How to repla...

Страница 3: ...a fine wood stove which works equally well for cooking and for cold winter evenings This manual provides instructions in how to install your wood stove and maintenance advice and tips on the best way...

Страница 4: ...hat installation be carried out by a professional Contact one of our dealers who can assist with the installation or recommend a suitable technician Building application When installing a fireplace an...

Страница 5: ...le Scheitholz Log wood Vedbr nsle Nennw rmeleistung Nominal heating capacity Nominell v rmekapacitet 3 5 kW Mindestabst nde Least distances Minimiavst nd Br nnbart Seitenwand Side wall Sida 500mm R ck...

Страница 6: ...6 JD 27 JD 227 WOOD BURNING RANGE This manual contains information about installation of JD 20 and JD 227 The difference between these to models is their front Josef Davidssons 227 Josef Davidssons 27...

Страница 7: ...ptimal operation All measurements are indicated in millimetres NOTE Keep in mind that the floor cover should be at least 300 mm in front and at least 100 mm on the sides of the fireplace opening 480 2...

Страница 8: ...n tested and approved with 100 mm of lightweight concrete or similar material as a firewall In a diagonal position remember that the dimensions are always taken from the centre of the outlet pipe Betw...

Страница 9: ...ovanf r spisen pga h g str lningsv rme m Minimiavst nd ll br nnbart material ovanf r spis 1 000 mm Lu spalt 5 10mm 100mm isen Minimum distance to material above the stove 1000mm NOTE Cooker hood must...

Страница 10: ...fitted with a throttle valve and a removable hotplate HERE IS HOW YOUR JD 27 JD 227 WORKS Combustion air Primary air is supplied when the fireplace door is slightly open during refill and during the f...

Страница 11: ...s 500 mm provided that the vertical flue length is at least 5 m It should be possible to sweep the whole length of the flue and the soot hatches should be easy to get at Check that the chimney is tigh...

Страница 12: ...thers go down into the floor and then out through the foundations If you go down into the floor it is important for the supply pipe to be insulated to counter condensation Contact your dealer if you a...

Страница 13: ...pwards to lift it out Then do the same with the left iron The rear iron is now loose and easy to lift 3 When installing the new parts start with the rear iron Then it left and finally the right iron 4...

Страница 14: ...ther types Otherwise you could risk damaging your firebox The wood must be dry ideally with 15 20 moisture content With normal firing around 1 1 5 kg wood hour should be sufficient 1 kg of birch wood...

Страница 15: ...damp Use only dry wood with a moisture content of 20 The throttle valve is closed too far Open the throttle valve to let in more air for combustion The glass turns white Poor combustion Follow the in...

Страница 16: ...for costs arising from downtime or other direct or indirect costs and damages The warranty conditions do not apply to glass or replaceable firebox parts The warranty period for the grate fire irons ve...