7
CLEANING INSTRUCTIONS
These instructions are for cleaning the KAPTIV-CS-HP-S. If your KAPTIV-CS-HP-S requires
maintenance, i.e. replacement of wearing components, please refer to our dedicated maintenance
instructions (supplied with the service kit).
Depressurise the system before installation or maintenance is carried out!
1. Close the condensate supply, i.e. close
the ball valve which is installed in front of
the KAPTIV-CS-HP-S.
2.Press the TEST button to empty the
unit of any residual condensate and to
depressurise the KAPTIV-CS-HP-S.
3. Switch off the electrical supply by
unscrewing the connector screw and
removing the power connector.
Make sure the display is off to check if the power
supply is successfully disconnected.
4. Open the housing by unscrewing the
four housing bolts using a 5 mm allen key and
remove the top part from the reservoir.
WARNING: please make sure the electronics
compartment does not get wet, this will damage the unit!
WARNING: The electronics compartment is
connected to the bottom part with a cable! Do
not damage this cable!
5. Slide de electronics up and unscrew the
valve from the bottom part of the housing
using a 23 mm wrench.
6. Clean the valve parts. Also clean the other
parts of the KAPTIV-CS-HP-S unit.
Содержание KAPTIV-CS-HP-S