SM096 EN REV03 2016_05
CONTROL
DISPLAY
USER MANUAL
To be kept by the purchaser
Control display for water heating products
Страница 1: ...SM096 EN REV03 2016_05 CONTROL DISPLAY USER MANUAL To be kept by the purchaser Control display for water heating products...
Страница 2: ...uct Please carefully read and keep this sheet before using the equipment The manual provides information and suggestions necessary for correct product use Knowing and observing these instructions will...
Страница 3: ...ERFACE 5 02 1 CONTROL DISPLAY DESCRIPTION 5 02 2 KEY FUNCTIONS 5 02 3 ICON MEANINGS 6 CAP 03 OPERATING MODE 6 03 1 APPLIANCE OPERATIONS 6 03 2 MAIN STATUS MESSAGE MEANINGS 7 03 3 MAIN SETTINGS 8 CHAP...
Страница 4: ...d by Jolly Mec Caminetti S p A The descriptions and illustrations provided in the following publication are not binding Jolly Mec Caminetti S p A reserves the right to make any modifications that may...
Страница 5: ...ESS Rapid access to adjust Set Water temperature in the appliance Decrease EDIT VALUE Decreases the selected setting value Chronothermostat ACTIVATE CRONO Pressed together with button 2 activates the...
Страница 6: ...on the display indicating that the switch on procedure is made up of various phases defined in technical parameter settings and to be set by a specialised Technical Service Center After the normal sw...
Страница 7: ...the device is increasing or decreasing output BASKET CLEANING Message displayed during the clean brazier automatic cycle that is run at regular intervals while the stove is running A forced ventilati...
Страница 8: ...ut level press Key 3 to return to the main page To change the required temperatures press Key 1 2 or 6 on the main page to immediately open the relevant section The set values can be changed using key...
Страница 9: ...er 5 SET STAND BY STAND BY mode lets you turn off the appliance when room or water temperature requests according to the set configuration are met In STAND BY display message the appliance is awaiting...
Страница 10: ...s 1 and 2 and press Key 4 to set the displayed value and move to the next page M1 004 DAY CLOCK To select the current day use Keys 1 and 2 and press Key 4 to set the displayed value and move to the ne...
Страница 11: ...to adjust the delay time When the appliance is OFF set DELAY ON for deferred appliance start or with the appliance in RUNNING set DELAY OFF to program shutdown The function is disabled when set to 00...
Страница 12: ...nd press Key 4 to confirm the selection and move to the next page M2 3 003 STOP 1 DAY Use Keys 1 and 2 to set the end time for the first operating time range permitted by the function and press Key 4...
Страница 13: ...SET ROOM T PROG 1 Use Keys 1 and 2 to set the room temperature value to be reached in the first time range and then press Key 4 to confirm the selection and move to the next page M2 4 005 MONDAY PROG...
Страница 14: ...M T PROG 1 Use Keys 1 and 2 to set the room temperature value to be reached in the first time range and then press Key 4 to confirm the selection and move to the next page The next three screens simil...
Страница 15: ...mode and in configuration 6 summer mode is automatically enabled When finished the message DONE will be displayed to confirm correct data entry Next the level page automatically returns to the Menu P...
Страница 16: ...it is not opened it is not possible to reset the CLEAN BRAZIER message After opening the door and cleaning the firebox press Key 3 to cancel the message and return to the main page that will display...
Страница 17: ...is displayed in this page M8 005 BUFF HI TEMP Puffer high temperature is displayed in this page M8 007 DHW TANK TEMP Boiler low temperature is displayed in this page M8 008 H2O PRESSURE Water pressure...
Страница 18: ...models with these settings M8 018 TEMP FLOW The debimeter heated sensor temperatures are displayed in this page for models with these settings M8 011 BOARD TEMP Electronic board temperature is display...
Страница 19: ...ase is displayed in this page M8 022 STATE STOVE Appliance status is displayed in this page MENU 9 TECHNIC SETTINGS Password protected Menu reserved to the Jolly Mec Customer Service CAT technician Th...
Страница 20: ...E SETTING MA 002 REGULATE CHIMNEY Use Keys 1 and 2 to adjust fume exhaust speed between 09 and 09 corresponding to 3 each unit and press Key 4 to confirm and move to the next page MENU B COUNTER MEMOR...
Страница 21: ...s page These pages similar to the previous page display total operating hours at the various output levels Mb 013 The first alarm stored in the memory is displayed on this page The following appear on...
Страница 22: ...e message DONE will be displayed to confirm correct data entry Next the level page automatically returns to the Menu Page MENU C SEASON When the counter reaches a value of 9999 displayed on the first...
Страница 23: ...temperature over 260 C limit Contact the specialised Technical Service Center An incorrect value was set in MAX RUN THRESH AL04 BROKEN FAN EXT Fume fan speed does not match the set point Contact the...
Страница 24: ...C Make sure the pump outlet to the system heating circuit is open in the event of dissipation that there are not passageway obstructions due to zone solenoid valve triggered by external components Mak...
Страница 25: ...obe wiring If correct replace the probe AL22 LO PROBE BUFFER The Puffer Lo probe is disconnected or broken Check probe wiring If correct replace the probe AL23 PELLET LEVEL If the level sensor is inst...
Страница 26: ...26 NOTES...
Страница 27: ...ENGLISH 27...
Страница 28: ...SM096 EN REV03 2016_05 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...