background image

www.johnsonandstarley.co.uk

USERS INSTRUCTIONS

WARMCAIR

Condensing Air & Water Heater

High Ef

fi

 ciency Down

fl

 ow

Condensing Air & Water Heater

Warmcair C10DW

   -   G.C. No.  43-417-59

Warmcair C16DW

   -   G.C. No.  43-417-60

Warmcair C20DW

   -   G.C. No.  43-417-61

These instructions are to be left with the User

43

Publication No. ZZ 1449 

July 2014

ater

-417-59

417

59

Содержание Warmcair C10DW

Страница 1: ...Air Water Heater High Efficiency Downflow Condensing Air Water Heater Warmcair C10DW G C No 43 417 59 Warmcair C16DW G C No 43 417 60 Warmcair C20DW G C No 43 417 61 These instructions are to be left with the User 43 Publication No ZZ 1449 July 2014 ater 417 59 417 59 ...

Страница 2: ...y Council For more information visit www centralheating co uk Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation The installer is legally required to complete a commissioning checklist a...

Страница 3: ...tat will then automatically allow the heater to cycle on and off to maintain the selected room temperature 2 3 CONTROL OF YOUR HEATING SYSTEM 2 3 1 You can control the heat to each room by opening and closing the warm air outlets but not more than half of these outlets should be closed at any one time or the performance of the heating system may be adversely affected 2 3 2 Warm air outlets in the ...

Страница 4: ...quirements and at least half of the warm air outlets are open especially in the room where the temperature control is sited 5 2 Check if the air filter is clogged and clean as instructed in Section 2 5 3 If the fan will not slow down or stop at any time ensure that the summer air circulation switch if fitted is set to OFF 5 4 SERVICE ARRANGEMENTS NEW APPLIANCES Service is supplied under guarantee ...

Страница 5: ...low 5 degrees C 4 During normal operation the burner on indicator will remain illuminated when the burner is lit Note If the heater fails to light after five attempts the fault code will be displayed 8 3 TO SHUT DOWN THE BOILER Set the mode to OFF To relight the heater repeat the procedure detailed in To light the heater 8 4 FROST PROTECTION If no system frost protection is provided and frost is l...

Страница 6: ...tered Gas Installer RGII 11 ESCAPE OF GAS Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay Telephone 0800 111 999 Do NOT search for gas leaks with a naked flame 12 CLEANING For normal cleaning simply dust with a dry cloth To remove stubborn marks and stains wipe with a damp cloth and finish off with a dry cloth DO NOT use abrasive cleaning materials ...

Страница 7: ...NG 1 DO KEEP CLEAN and make sure you DO NOT OBSTRUCT any grilles on the heater in the heater compartment or in any walls windows or doors of the building 2 DO CLEAN AND REFIT the air filter at least once per month 3 DO NOT PLACE ANYTHING clothing linen etc in contact with the air heater or its flue pipe 4 DO NOT USE the heater compartment for storage or airing 5 DO NOT turn off the mains electrici...

Страница 8: ...4 7LZ sales johnsonandstarley co uk marketing johnsonandstarley co uk Reception Customer Service 01604 762881 Fax 01604 767408 Johnson Starley Dravo Division Industrial H V Sales 01604 707022 sales johnsonandstarley co uk www dravo co uk Anniversary 1922 2012 ...