background image

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) 

Room Thermostats Installation Instructions

 Refer to the 

QuickLIT website

 for the most up-to-date version of this document.

1

Application

The WT-4000 Series Pneumatic-to-Direct Digital 
Control (DDC) Room Thermostats provide reliable 
zone comfort and enhanced energy economy via 
remote monitoring and temperature setpoint 
management. This arrangement provides greater 
energy policy compliance, and facilitates trending of 
floor space usage in commercial, industrial, and 
municipal HVAC environments.

The WT-4000 Series Room Thermostats are ideally 
suited for energy-saving, pneumatic-to-DDC building 
upgrades. Designed for non-invasive replacement 
of existing manual pneumatic thermostats, the 
WT-4000 Series Room Thermostats provide a number 
of DDC features, including remote wireless setpoint 
control and occupancy scheduling, and continuous 
room temperature, branch line pressure, and battery 
status monitoring. All of these features were previously 
unavailable in existing pneumatic HVAC control 
systems.

The innovative design of the WT-4000 Series Room 
Thermostats completely reshapes the pneumatic 
HVAC control industry. The room thermostat itself does 
not utilize any mechanical parts. A solid state 
temperature sensor replaces the bi-metallic strip 
elements for precise room temperature monitoring. In 
addition, an advanced piezoelectric air valve replaces 
the mechanical relay for improved branch line pressure 
control. All of these technologies provide longer, more 
dependable, and maintenance-free operation.

Models are available for wireless mesh 
communications, or they can be configured in the field 
for stand-alone applications. In a wireless mesh 
network application, the WT-4000 Series Room 
Thermostat communicates with the controller by 
means of a Johnson Controls® WT-ROUTER Router 
and Johnson Controls WT-BAC-IP Gateway.

Some WT-4000 Series Room Thermostats include a 
binary dry contact input for an occupancy sensor (field 
furnished), to detect motion and determine if a space is 
occupied. This feature maximizes up to 30% energy 
savings in high-energy usage environments such as 
schools, dormitories, offices, and hospitals by adjusting 
the temperature of the space based on the occupancy 
status.

All WT-4000 Series Room Thermostats include an 
LCD, with either a Fahrenheit or Celsius temperature 
display. Depending on the model chosen, the room 
thermostat can transmit sensed temperature, setpoint 
temperature, occupancy status, and low battery 
conditions to an associated router and gateway. The 
WT-4000 Series Room Thermostat is designed for 
indoor, intra-building applications only.

The WT-4000 Series uses a proprietary 
direct-sequence, spread-spectrum RF technology, 
and operates on the 2.4 GHz Industrial, Scientific, and 
Medical (ISM) band. The room thermostat meets the 
IEEE 802.15.4 standard for low power, low duty cycle 
RF transmitting systems.  

   

IMPORTANT:

The WT-4000 Series 

Pneumatic-to-DDC Room Thermostat is intended to 
provide an input to equipment under normal 
operating conditions. Where failure or malfunction of 
the room thermostat could lead to personal injury or 
property damage to the controlled equipment or 
other property, additional precautions must be 
designed into the control system. Incorporate and 
maintain other devices, such as supervisory or 
alarm systems or safety or limit controls, intended to 
warn of or protect against failure or malfunction of 
the room thermostat.

IMPORTANT:

Le WT-4000 Series 

Pneumatic-to-DDC Room Thermostat est destiné à 
transmettre des données entrantes à un équipement 
dans des conditions normales de fonctionnement. 
Lorsqu'une défaillance ou un dysfonctionnement du 
room thermostat risque de provoquer des blessures 
ou d'endommager l'équipement contrôlé ou un autre 
équipement, la conception du système de contrôle 
doit intégrer des dispositifs de protection 
supplémentaires. Veiller dans ce cas à intégrer de 
façon permanente d'autres dispositifs, tels que des 
systèmes de supervision ou d'alarme, ou des 
dispositifs de sécurité ou de limitation, ayant une 
fonction d'avertissement ou de protection en cas de 
défaillance ou de dysfonctionnement du room 
thermostat.

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) 
Room Thermostats

Installation Instructions

WT-4002-MCR, WT-4002-MCM,
WT-4002-MFR, WT-4002-MFM

Part No. 24-10732-5, Rev. D

Issued August 2017

24- 10732- 5,  Rev .  D

Содержание WT-4002-MCM

Страница 1: ...nergy savings in high energy usage environments such as schools dormitories offices and hospitals by adjusting the temperature of the space based on the occupancy status All WT 4000 Series Room Thermo...

Страница 2: ...e should be at least two routers or one router and one gateway located within a 200 ft 61 m radius of every room thermostat In order for the devices to connect to the same mesh network they all must h...

Страница 3: ...reless network before installation by identifying room thermostat locations To document the location of where each wireless device is installed Mounting Procedure Mount the WT 4000 Series Room Thermos...

Страница 4: ...ialization 7 Check the wireless connectivity at the intended room thermostat installation location It may take approximately 30 seconds for the room thermostat to initialize a Look at the wireless con...

Страница 5: ...the following An air dryer that is operating properly A coalescing air filter that is replaced and maintained properly In line air filters before each room thermostat where necessary Order of Installa...

Страница 6: ...ers Manual Override Occupied Mode Light Button Lights the Display for 10 Seconds Up Button Increases the Room Temperature Setpoint Down Button Decreases the Room Temperature Setpoint LCD See Figure 4...

Страница 7: ...onnected to the WT BAC IP Gateway b 1 One connection exists c 2 Two or more connections exist and the room thermostat is operating properly Battery Voltage Level a The battery is fully charged b The b...

Страница 8: ...LCD reads Setpoint Note When the room temperature and the setpoint value are the same the HVAC equipment is off b If neither the Up or Down button is pressed again the LCD returns to the main screen...

Страница 9: ...late from the room thermostat 2 Install the four 3 6 V lithium batteries included with the room thermostat into the battery compartment Be sure to match the positive battery ends with the positive bat...

Страница 10: ...the Up Down buttons to select the Maintenance option Figure 8 2 Press to confirm the selection 3 Press the Up Down buttons to select the Dir Acting SP Psi Gain Prop Bnd or Unoc Psi option Figure 9 4 P...

Страница 11: ...oportional band proportional range throttling range The valid range is 0 to 10F 0 to 6C adjustable in increments of 1F 0 6C The default setting is 6F 3 6C b Press the Down button to decrease the propo...

Страница 12: ...255 1 111 111 DI to change the unique thermostat device ID Two fields separated by a period first field is 1 through 159 and second field is 1 through 246 1 71 40 Pneumatic Direction Direct acting br...

Страница 13: ...ust the operation of HVAC equipment manually outside of the schedule but within set energy policy parameters The WT 4000 Series Room Thermostats are designed to support any 0 to 22 psig 0 to 152 kPa p...

Страница 14: ...remote monitoring adjustment and trending to provide longer and more dependable and maintenance free operation Note For each room thermostat in the wireless mesh network only one object can be writte...

Страница 15: ...o the occupancy schedule A complete 7 day schedule consists of two independent components Weekday Schedule Monday through Friday Weekend Schedule Saturday through Sunday Each component is split into t...

Страница 16: ...part is being edited Occupied or Unoccupied Defines the occupancy mode of the part Time in 24 Hour Format Defines the start time of the part FIG occpd_mde Figure 18 WT 4000 Series Pneumatic to DDC Ro...

Страница 17: ...right corner of the LCD indicating stand alone operation Stand Alone Room Thermostat Configuration To set the time and program the stand alone room thermostat occupancy schedule and temperature setpo...

Страница 18: ...use the Up Down buttons to navigate to Weekday to program the weekday schedule 10 Press to open the weekday schedule 11 Set the Weekday 1 schedule Figure 25 which is usually the start of the Occupied...

Страница 19: ...cy mode start time upper temperature limit and lower temperature limit menu items f Press to open a specific menu item g Press the Up button or the Down button to change the value then press to save t...

Страница 20: ...pied from 3 P M to 6 A M Monday through Sunday Program the WT 4000 Series Room Thermostat schedule setup screen as illustrated in Figure 29 Weekend 1 Unoccupied 09 00 85 55 Weekend 2 Unoccupied 17 00...

Страница 21: ...tat allows users to adjust the room temperature using the local room thermostat as long as the desired room temperature is within the range of the Comfort Zone If the user requests heating or cooling...

Страница 22: ...ning a 5 day 8 A M to 6 P M occupancy schedule but one day the occupants are leaving at 2 P M the zone can be manually set into Shoulder Mode at 2 P M The room thermostat remains in Shoulder Mode unti...

Страница 23: ...its Configuration tool Override Mode Override duration default 120 minutes Room thermostat override duration 240 minute maximum duration after time limit expires room thermostat goes into regularly sc...

Страница 24: ...wer delta Defines lower temperature limit in Shoulder Mode Configuration tool Direction Direct acting branch line pressure increase turns on cooling decrease turns on heating Reverse acting branch lin...

Страница 25: ...F maximum 14 F AV 31 Shoulder_Up_D Upper delta default 5 F In shoulder mode the device does not call for cool if space temperature is below setpoint plus upper delta AV Shoulder_Lo_D Lower delta defa...

Страница 26: ...ne pressure of the system at that time in PSI AI 79 Temp_Unit The unit of temperature 0 represents F and 1 represents C The default is F Any change to this value reboots the device AV MS_Grace The gra...

Страница 27: ...Display LCD indicates room temperature branch line pressure temperature setpoint occupied setback mode battery voltage and wireless connection status supports temperature setpoint adjustment network c...

Страница 28: ...he marks of their respective owners 2017 Johnson Controls Building Technologies Solutions 507 E Michigan Street Milwaukee WI 53202 28 European Single Point of Contact NA SA Single Point of Contact APA...