Section 4: Programming Options
WLAN SSID
This section is used to program a network name (unique
identifier) for the panel.
Default:
None
Valid range:
Alphanumeric
WLAN Client Control
This option is used to control WiFi client mode.
Default:
Enabled
Valid range:
Enabled/Disabled
WLAN Security Type
This option is used to select which encryption protocol the
system uses to secure the wireless network.
Default:
WPA2 PSK AES
Valid range:
WPA PSK TKIP
WPA PSK AES
WPA PSK TKIP AES
WPA2 PSK TKIP
WPA2 PSK AES
WPA2 PSK TKIP AES
MIXED MODE TKIP
MIXED MODE AES
MIXED MODE TKIP AES
WLAN Security Key
This section is used to program a password for the Wi-Fi net-
work.
Default:
None
Valid range:
32 character ASCII
Panel's Cellular Public APN
This section is used to program the Access Point Name of
the network used for cellular-data connectivity.
Default:
Blank
Valid range:
32 ASCII characters or Null
Panel's Cellular Login User Name
This section is used to program a user name for cellular net-
work connection.
Default:
Blank
Valid range:
32 ASCII characters or Null
Panel's Cellular Login Password
This section is used to program a user password for cellular
network connection.
Default:
Blank
Valid range:
32 ASCII characters or Null
Time Zone
This option defines the time zone that the alarm system will
operate in.
From the list of valid entries, locate and select the appro-
priate time zone.
Default: US Eastern
Valid
range:
US-Alaska, US-Aleutian, US-Arizona, US-Central, US-Eastern, US-
Hawaii, US-Indiana-East, US-Indiana-Starke, US-Michigan, US-Moun-
tain, US-Pacific, US-Samoa, CA-Atlantic, CA-Central, CA-Eastern,
CA-Mountain, CA-Newfoundland, CA-Pacific, CA-Saskatchewan, CA-
Saskatchewan-East, CA-Yukon
4.3 Central Monitoring Station
Programming Options
The following section provides descriptions of all pro-
gramming options for communications between the iotega
and the central monitoring station.
Communication Path
Use this option to select the method by which the panel com-
municates to the central monitoring station. Choose one of
the following:
None: The system does not communicate to the central mon-
itoring station via Ethernet or Cellular.
Ethernet: The system communicates to the central mon-
itoring station via Ethernet connection only.
Cellular: The system communicates to the central monitoring
station via cellular connection only.
Ethernet and Cellular: The system communicates to the cent-
ral monitoring station via Ethernet as the primary path and
cellular as the secondary path.
Default:
None
Valid range:
None, Ethernet, Cellular, Ethernet and Cellular
CMS Ethernet 1 Account Code
This option is used to program an account code used by the
central monitoring station to identify the ethernet transmitter.
Programming all 0’s or all F’s causes a module con-
figuration trouble.
Note:
If both Ethernet Receiver 1 and Cellular Receiver 1
are the same receiver (IP and port number are identical), Eth-
ernet Receiver 1 account is used for Ethernet and Cellular.
Note:
An Ethernet account code is necessary in order for the
iotega to communicate to the central monitoring station (if
Ethernet communication path is selected).
Default:
0000000000
Valid range:
0000000000 to FFFFFFFFFF
CMS Ethernet 1 DNIS
The Dialed Number Information Service (DNIS) is used in
addition to the account code to identify the communicator
module at the central monitoring station.
Default:
000000
Valid range:
000000 to 0FFFFF (first digit not used)
- 21 -