background image

 

 
D-307788 MP-843/XHM2 

1

 

 

Installation Guide

 

 

MP-843/XHM2 

ZigBee 3.0 Home Automation 
Wireless Digital Pet Immune PIR Motion Detector

 

 

Introduction 

The MP-843/XHM2 PIR motion detector is wireless,  digital, and immune 

to the movements of pets. The detector is controlled by a micro-

processor and supports ZigBee 3.0. The detector has the following 

features: 

 

 

 

Detection distance of up to 49 ft. 

 

Uniform detection. 

 

White light immunity  

Note:

 This feature is not evaluated  by UL. 

 

Target Specific Imaging™ (TSI) enables immunity from pets  

weighing up to 85 lb.  

Note:

 This specification is not evaluated by UL. 

 

The patented True Motion Recognition™ algorithm  enhances false   

alarm rejection.   

 

Requires no vertical adjustment. 

 

To save battery power, the detector goes to sleep after a detection  

while  in normal mode. If there is no detection during the following  

2-minute period, the detector returns to a ready state. 

 

Temperature compensation. 

 

Front tamper protection. 

 

Black mirror  technology provides excellent white light protection. 

 

Elegant, sturdy case. 

Figure 1: Legend

 

 

 

Callout

 

Description

 

1

 

Red LED

 

2

 

Green LED

 

3

 

Tamper switch

 

Specifications 

 

Detector type: dual element low-noise pyroelectric sensor 

 

Optical data:  

o

 

9 far parabolic black mirrors provide 18 beams. 

o

 

5 near cylinder  black mirrors  provide 10 curtains.  

o

 

An optical attenuator on the mirror provides pet immunity 

protection. 

 

Maximum coverage: 90° and 15 x 15 m or 49.2 ft x 49.2 ft   

 

Pet immunity: up to 85 lb 

Electrical 

 

Internal batteries: two 3 V CR-123A lithium batteries.   

Note:

 For UL installations,  use only GP batteries. 

 

Nominal battery capacity: 1400 mAh 

 

Battery life: over 5 years * 

Note:

  

 

The battery life reduces faster if  the device cannot connect to 

a wireless  network or the wireless  connection quality is lower 

than 20%. 

 

This specification is not evaluated by UL. 

 

Battery power test: occurs when you insert  the battery  and 

periodically every several hours 

Functional 

 

Alarm period: 3 s 

 

Visual indications:  

o

 

The red LED lights for 3 seconds when the detector transmits 

an alarm or tamper message.  

o

 

The red LED lights for 3 seconds when the detector detects 

motion while it is in walk test mode. 

Note:

 Outside of walk test mode, the red LED does not light 

when the detector detects alarm, or when it sends 

transmission or supervision messages. 

o

 

The red LED flashes during the power-up stabilization  period 

and when you press the tamper switch 

 

Rearm timer: rearms the detector 2 minutes after the last alarm. 

The timer is disabled in walk test mode. 

Wireless 

 

Supported network: ZigBee 3.0 

 

Frequency: 2.405  to 2.480 Ghz as per IEEE 802.15.4 

 

Tamper alert:  reports when a tamper  event occurs and in any 

subsequent message until the tamper switch is restored 

Mounting 

 

Height: 6 ft to 7 ft.  For pet  immunity, the optimal height is 7 ft. 

 

Installation options: flat surface or corner 

Environmental 

 

RFI protection: >20 V/m up to 1000 MHz 

 

Operating temperatures:  -10°C or 14°F to 50°C or 122°F 

 

Storage temperatures:  -20°C or -4°F to 60°C or 140°F 

Physical 

 

Size (H x W x D): 4.68 in. x 3.11 in. x 1.31 in. 

 

Weight including batteries: 4.2 oz. 

 

Color: white 

 

Patent: U.S. patents 5,693,943  and 6,211,522 

Installation 

General Guidance 

Note:

 Install the device in accordance with the Standard for 

Installation and Classification  of Residential  Alarm Systems, UL 1641. 

Do not install  the device in any of the following locations. See Figure 

2: 

1.

 

Near high-voltage electrical  lines 

2.

 

Near heat sources 

3.

 

Outdoors  

4.

 

In direct  sunshine 

5.

 

In an area exposed to air drafts 

Содержание Tyco Visionic MP-843/XHM2

Страница 1: ...tery life reduces faster if the device cannot connect to a wireless network or the wireless connection quality is lower than 20 This specification is not evaluated by UL Battery power test occurs when you insert the battery and periodically every several hours Functional Alarm period 3 s Visual indications o The red LED lights for 3 seconds when the detector transmits an alarm or tamper message o ...

Страница 2: ... Replacing the batteries Pairing the detector and the panel Pair the detector and control panel before you install the detector Note For UL listed installations only use the device with UL listed control panels 1 Set the panel to pairing mode For more information refer to the panel user guide 2 Set the detector to pairing mode 3 To activate the detector pull the activation strip that protrudes fro...

Страница 3: ...ries The device transmits a low battery indication To ensure continuous full operation replace both batteries within two weeks of the first low battery indication The panel does not arm because of an unrecognized detector malfunction Disable the zone For more information refer to the control panel user guide Note Consult with your installer or system provider before you disable a zone The overall ...

Страница 4: ...AL OR INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER AS AFORESAID THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS DAMAGE OR EXPENSE INCLUDING LOSS OF USE PROFITS REVENUE OR GOODWILL DIRECTLY OR INDIRECTLY ARISING FROM PURCHASER S USE OR INABILITY TO USE THE PRODUCT OR FOR LOSS OR DESTR...

Отзывы: