Section 2: Installation
2.4 General wiring instructions
Warning: Disconnect AC power before servicing.
To connect the wiring for the PowerSeries Pro, complete the following steps:
1. Insert thestandoffs into the cabinet mounting holes in the desired location. Snap into place.
2. Position circuit board over the standoffs. Press firmly on board to snap into place.
3. Route the AC line into the enclosure through the provided opening.
4. Route the DC wires to the alarm controller.
5. Route wiring for modules/devices into the enclosure through provided openings. Remove knockouts in the cabinet as required.
6. Wire the tamper switch to any Corbus zone. Program zone as 24-hour latching or non-latching tamper. Supports NC, EOL or
DEOL supervision.
7. Use cable ties to secure all wires to the enclosure.
Note:
For the HSC3030CAR attack-resistant enclosure, cover all unused holes with plastic plugs that are shipped with the cabinet.
Note:
Do not connect power adapter module to receptacle controlled by a switch.
Power supply wiring
The power supplyadapter can be mounted outside the cabinet. Use the following guide to determine suitable distance and gauge:
Distance (m / ft)
Gauge (AWG)
2 / 6.5
22
3 / 10
20
4 / 13
18
- 18 -