Section 6: Programming
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[002] Tampers (Including System Tampers)/ Restore
These options control which receiver paths are enabled for Partition 1-32 Tamper and Restore event reporting codes.
To assign an event to a receiver, select one of the following options:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[003] Openings/ Closing
These options control which receiver paths are enabled for Partition 1-32 Opening and Closing event reporting codes. To assign an
event to a receiver, select one of the following options:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[350] Communicator Formats
Use this programming option to assign a communicator format to each of the four receivers programmed in section [301]. The
available communicator formats are as follows:
Programming option
Communicator format
03
DTMF Contact ID
04
SIA FSK
To assign a communications format, select a receiver (option [001]-[004]) then enter the 2-digit code corresponding to the chosen
format. For detailed descriptions of each format, see
[377] Communication Variables
[001] – Swinger Shutdown
Alarms/Restores
This value defines the number of communication attempts made for alarm/restore events, per zone, before the zone goes into
swinger shutdown. Valid entries are 000 to 014. For CP-01, entries are from 001-006.
Once the programmed number of alarm/restore events have been communicated, no further alarm/restore events for the zone are
communicated until swinger shutdown is reset. The last restore event is not communicated until swinger is cleared. For example, if
the swinger shutdown limit for zone alarms is set to [003], the cycle is as follows: alarm/restore, alarm/restore, alarm...8 hours or
arm/disarm...restore.
The bell output is not activated for alarms on zones that have exceeded the swinger shutdown counter limit. Swinger shutdown on
global zones log once to the system area.
CP-01
Note:
Swinger shutdown resets on all partitions when any partition on the system is armed or disarmed, or every day at midnight. For
CP-01, swinger shutdown is restored after 8 hours of inactivity.
Once reset, the alarm system communicates normally.
Note:
The event buffer can follow swinger shutdown if enabled.
Tampers/Restores
This value defines the number of times the same system tamper event occurs before going into swinger shutdown. Valid entries are
000 to 014.
Maintenance Troubles/Restores
This value defines the number of times the same system Maintenance (trouble) type event occurs before going into swinger
shutdown. Fire troubles follow the Maintenance Swinger Shutdown variable.
- 131 -