background image

T7603-T000-...JF0

T7600-TB21-…JA0

Application

VAL

Floor heater

Floor heater water valve

Application

AO

AI

2-pipe FCU, AO valve Valve

Actuator feedback

GND

B

A

GND NTC OCC COM

L

VAL

N

T7601-TF20-...JS0

Application

AO1 VAL2

VAL1

2-pipe relay valve

N/A

N/A

Valve

4-pipe relay valve

Heating

Cooling

2-pipe 3-wire relay valve

Valve off Valve on

2-pipe relay valve with 

TiO2/ESP

TiO2/ESP Valve

2-pipe relay valve with 

floor heating

Floor 

heating

Valve

Water source heat pump

Reversing Compressor

2-pipe AO valve

Valve N/A

N/A

Notes: F-ON is line voltage relay output, used for enable/

disable ECM fan in some case

FAN AO1

F-ON

VAL2

VAL1

GND

B

A

GND NTC OCC COM

L

N

T7600-TF21-...JS0

Application

AO2

AO1

2-pipe FCU

N/A

Valve

4-pipe FCU

Heating

Cooling

AO2

GND

B

A

AO1 GND NTC OCC COM

L

HI

MED

LOW

N

AI

GND

B

A

AO GND NTC OCC COM

L

HI

MED

LOW

N

T7600-TF20-...JS0

Application

VAL2

VAL1

2-pipe relay valve

N/A

Valve

4-pipe relay valve

Heating

Cooling

2-pipe 3-wire relay valve Valve off

Valve on

2-pipe relay valve with 

TiO2/ESP

TiO2/ESP

Valve

2-pipe relay valve with 

floor heating

Floor heating Valve

Water source heat pump Reversing

Compressor

GND

B

A

GND NTC OCC COM

L

HI

MED

VAL2

VAL1

LOW

N

Содержание T7000 Series

Страница 1: ...the most up to date version of this document Figure 1 Figure 4 1 Figure 2 Figure 3 o F AUTO 50 cm 19 68 inch 150 cm 59 05 inch C Ambient Ambiante Umgebung Ambiente Ambiente Atmosfeer Omgivnin Prost e...

Страница 2: ...pipe AO valve Valve N A N A Notes F ON is line voltage relay output used for enable disable ECM fan in some case FAN AO1 F ON VAL2 VAL1 GND B A GND NTC OCC COM L N T7600 TF21 JS0 Application AO2 AO1 2...

Страница 3: ...cording to local national and regional regulations Failure to ground the thermostat may result in electrical shock and severe personal injury and death Risk of Electrical Shock and Property Damage Ins...

Страница 4: ...guage 00 Chinese 01 English 00 22 Mode selection 00 cooling heating ventilation 01 cooling only 02 heating 00 23 Back light The back light will be OFF in 05 60 Sec 30 25 Remote sensor type 00 China ma...

Страница 5: ...21 JA0 01 T7601 TF20 JS0 00 2 01 4 02 2 3 03 2 TiO2 ESP 04 2 05 06 2 T7600 TF21 JS0 00 2 01 4 T7600 TF20 JS0 00 2 01 4 02 2 3 03 2 TiO2 ESP 04 2 05 00 02 2 40 36 99o F 35 03 0 38 32 95o F 5 04 22 32 7...

Страница 6: ...03 04 00 15 00 01 00 16 00 01 2 FCU 10K NTC 00 17 BI 00 01 02 03 04 05 06 00 18 00 01 o F 00 19 5 5 9 9o F 0 20 00 01 MED LOW 02 LOW 03 00 21 00 01 00 22 00 01 02 00 23 05 60s xx 30 25 00 10KNTC 01 J...

Страница 7: ...Point of Contact JOHNSON CONTROLS C O CONTROLS PRODUCT MANAGEMENT NO 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Technologies Solutions Headquarters Milwaukee Wisconsin USA Br...