4-pole left top connector

2-pole right top connector

5-pole bottom connector

Cool 1

Fan

24 VAC

Thermostat Power

Heat 1

Y1

G

RC

C

RH

W1

D1

D2

Scom

RS

If using the same power source
for the thermostat and heating
loads, install a jumper
across RC and RH.

Remote

Room

Sensor

Function

Terminal

Energizes on call for heating
Energizes on call for cooling
Energizes fan in accordance with the selected fan mode
24 VAC from equipment transformer
24 VAC (common  from equipment transformer
24 VAC for heating stage
Configurable digital input
Configurable digital input
Remote room sensor
Sensor common
Outdoor air sensor

)

W1

Y1

G

RC

C

RH

D1
D2

RS

Scom

OS

OS

OS

 

Figure 5: T600HCN-1 Wiring Schematic 

Setup and Adjustments 

Thermostat Operation Overview 

75.0ºF

Backlit, plain text, Liquid
Crystal Display (LCD)
is easy to read in any
condition.

Five keys on the T600
make operation easy
and intuitive.

Light Emitting Diodes (LEDs)
indicate system activity.

Room Temp

 

Figure 6: T600HCN-1 Front Cover 

T600HCN-1 Non-Programmable Thermostat Installation Instructions    

3

 

Содержание T600HCN-1

Страница 1: ...the thermostat cover see Figure 1 2 Unlock the Printed Circuit Board PCB by carefully pressing the locking tabs to the right see Figure 2 Open the thermostat s PCB to the left 3 Pull out approximatel...

Страница 2: ...e the thermostat 1 Strip each wire 1 4 in 6 35 mm and connect to the appropriate terminal according to the wiring diagram see Figure 5 2 Gently push excess wire back into wall plug the wall hole with...

Страница 3: ...24 VAC from equipment transformer 24 VAC common from equipment transformer 24 VAC for heating stage Configurable digital input Configurable digital input Remote room sensor Sensor common Outdoor air s...

Страница 4: ...uring normal thermostat operation The menu continually scrolls through the following parameters see Figure 6 Room Temperature System Mode Schedule Status Occupied Unoccupied see Note Outdoor Temperatu...

Страница 5: ...Maximum Cooling Cycles per Hour Cool cph Sets the Minimum Heating Cooling Deadband Default 2 0 F 1 1 C See Setting the Heating Cooling Deadband Deadband Determines how the Fan Activates in Response to...

Страница 6: ...nfigure Digital Input 2 or NO to advance to the keypad lockout setup prompt 4 Use the UP DOWN arrow keys to locate the desired function for the Digital Input 2 Press YES to select the desired function...

Страница 7: ...ows the minimum cooling setpoint prompt See the Setting the Minimum Cooling Setpoint Cool min section for instructions Setting the Minimum Cooling Setpoint Cool min The minimum cooling setpoint establ...

Страница 8: ...hes the minimum difference between the heating and cooling setpoints The range is adjustable from 2 to 4 F 1 to 2 C To change the minimum deadband between the heating and cooling setpoints while in th...

Страница 9: ...the display Press YES to enter the outdoor sensor calibration menu 2 Use the UP DOWN arrow keys to adjust the correction that should be applied to the sensor reading Press YES to store the offset The...

Страница 10: ...de schedule prompt only appears when the thermostat is in the unoccupied state This menu selection gives the user the option of overriding the unoccupied setpoints with the occupied setpoints for the...

Страница 11: ...et prompt appears in the display it may be the first prompt Press YES to enter temperature setting menu Press YES to change occupied cooling setpoint Press NO to advance to occupied heating setpoint m...

Страница 12: ...rn to the Status Display Menu or NO to return to the fan mode selection menu Setting Permanent Hold Note Displayed only if Digital Input DI1 or DI2 is configured for remote NSB This menu is used to se...

Страница 13: ...d to comply with the limits for a Class A digital device and verified to Class B pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interferenc...

Отзывы: