Operation Guideline
Product Model: KONOzw
Copyright
Johnson Controls Inc 2019
All Rights Reserved
Page 12 of 19
14
2
Ambient Temperature Change Step-
size
0.5F (0.25C) : 50
1.0F (0.50C) : 100
1.5F (0.75C) : 150
2.0F (1.00C) : 200
2.5F (1.25C) : 250
3.0F (1.50C) : 300
3.5F (1.75C) : 350
4.0F (2.00C) : 400
50
0.5F – 4F range with a step-size
of 0.5F (0.25C):
15
1
Regular Ambient Temperature
Reporting Interval
1-24
4
1 - 24 hours
16
1
Regular Operating State Reporting
Interval
1-24
4
1 - 24 hours
17
1
Command Echo for
- Thermostat Mode
- Thermostat Fan mode
- Thermostat Setpoint
0 or 1
0
0 - disable
1 - enable
6.5 OTA Firmware Upgrade
KONOzw complies with the Z-wave standard to perform the OTA firmware upgrade on the Host Processor.
User can follow the steps below to activate and verify the OTA upgrade process.
Step 1. Upload the provided OTA image to the hub and push the image to KONOzw
Step 2. Wait for around ~45mins until KONOzw has completed the firmware download and installation
process. The total time may vary depending on the data rate of the hub.
Step 3. When the OTA upgrade is completed, check the Host firmware version on the KONOzw LCD display.
To check the firmware versions:
•
In HOME screen, press the knob to enter main menu and select the setting option